{"title":"雷电电流分布建模中供电变压器及住宅电器的频率特性","authors":"S. Wyderka, G. Masłowski, R. Ziemba, G. Karnas","doi":"10.1109/ICLP.2012.6344344","DOIUrl":null,"url":null,"abstract":"Investigations were conducted aimed on examination of frequency characteristics of middle to low voltage distribution transformer used to supply residential buildings. Two methods were used for the investigations. First, the impedances (absolute values and angles) of transformer middle and low voltage windings were measured and registered using precision LCR meter for frequency range from 20 Hz to 10 MHz. These impedance characteristics were also examined using voltage surge generator and digital oscilloscope. Registered voltage and current waveforms were denoised and transformed to frequency domain. Apart from investigation of distribution transformer the frequency characteristic of input impedances of typical household electrical appliances were examined using the LCR meter. The conducted measurements are significant part of investigations concerning the lightning and overvoltage protection of residential buildings, which are conducted at the test site belonging to Rzeszow University of Technology.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Frequency characteristics of supplying transformer and electrical appliances of residential building in modeling of lightning current distribution\",\"authors\":\"S. Wyderka, G. Masłowski, R. Ziemba, G. Karnas\",\"doi\":\"10.1109/ICLP.2012.6344344\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Investigations were conducted aimed on examination of frequency characteristics of middle to low voltage distribution transformer used to supply residential buildings. Two methods were used for the investigations. First, the impedances (absolute values and angles) of transformer middle and low voltage windings were measured and registered using precision LCR meter for frequency range from 20 Hz to 10 MHz. These impedance characteristics were also examined using voltage surge generator and digital oscilloscope. Registered voltage and current waveforms were denoised and transformed to frequency domain. Apart from investigation of distribution transformer the frequency characteristic of input impedances of typical household electrical appliances were examined using the LCR meter. The conducted measurements are significant part of investigations concerning the lightning and overvoltage protection of residential buildings, which are conducted at the test site belonging to Rzeszow University of Technology.\",\"PeriodicalId\":400743,\"journal\":{\"name\":\"2012 International Conference on Lightning Protection (ICLP)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2012.6344344\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Frequency characteristics of supplying transformer and electrical appliances of residential building in modeling of lightning current distribution
Investigations were conducted aimed on examination of frequency characteristics of middle to low voltage distribution transformer used to supply residential buildings. Two methods were used for the investigations. First, the impedances (absolute values and angles) of transformer middle and low voltage windings were measured and registered using precision LCR meter for frequency range from 20 Hz to 10 MHz. These impedance characteristics were also examined using voltage surge generator and digital oscilloscope. Registered voltage and current waveforms were denoised and transformed to frequency domain. Apart from investigation of distribution transformer the frequency characteristic of input impedances of typical household electrical appliances were examined using the LCR meter. The conducted measurements are significant part of investigations concerning the lightning and overvoltage protection of residential buildings, which are conducted at the test site belonging to Rzeszow University of Technology.