流水线adc系统简化测试技术

E. Peralías, A. Ginés, A. Rueda
{"title":"流水线adc系统简化测试技术","authors":"E. Peralías, A. Ginés, A. Rueda","doi":"10.1109/ETS.2014.6847818","DOIUrl":null,"url":null,"abstract":"This paper presents a procedure to implement a high efficient test of the Integral Non-linearity (INL) of Pipeline ADCs using an extremely reduced set of test input amplitude levels (one order of magnitude lower than the total number of codes in the ADC). For a given architecture, the method provides the way to determine these levels to robustly capture the nonlinearity information. The location of each test level within the input range has low sensitivity to the internal ADC noise, and therefore, they are a good basis to continuously monitor the impact of process, aging and environment conditions variations (PVT) on the non-linearity, as well as miscalibration and possible failures in both foreground and background applications. The proposed method has been validated by realistic behavioral models in several examples.","PeriodicalId":145416,"journal":{"name":"2014 19th IEEE European Test Symposium (ETS)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"INL systematic reduced-test technique for Pipeline ADCs\",\"authors\":\"E. Peralías, A. Ginés, A. Rueda\",\"doi\":\"10.1109/ETS.2014.6847818\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a procedure to implement a high efficient test of the Integral Non-linearity (INL) of Pipeline ADCs using an extremely reduced set of test input amplitude levels (one order of magnitude lower than the total number of codes in the ADC). For a given architecture, the method provides the way to determine these levels to robustly capture the nonlinearity information. The location of each test level within the input range has low sensitivity to the internal ADC noise, and therefore, they are a good basis to continuously monitor the impact of process, aging and environment conditions variations (PVT) on the non-linearity, as well as miscalibration and possible failures in both foreground and background applications. The proposed method has been validated by realistic behavioral models in several examples.\",\"PeriodicalId\":145416,\"journal\":{\"name\":\"2014 19th IEEE European Test Symposium (ETS)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 19th IEEE European Test Symposium (ETS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ETS.2014.6847818\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 19th IEEE European Test Symposium (ETS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ETS.2014.6847818","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

本文提出了一种高效测试流水线ADC的积分非线性(INL)的方法,该方法使用一组极简的测试输入幅度电平(比ADC中的代码总数低一个数量级)。对于给定的体系结构,该方法提供了确定这些级别以鲁棒捕获非线性信息的方法。每个测试电平在输入范围内的位置对内部ADC噪声的灵敏度较低,因此,它们是连续监测过程、老化和环境条件变化(PVT)对非线性的影响,以及前景和背景应用中的误校准和可能的故障的良好基础。通过实例验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
INL systematic reduced-test technique for Pipeline ADCs
This paper presents a procedure to implement a high efficient test of the Integral Non-linearity (INL) of Pipeline ADCs using an extremely reduced set of test input amplitude levels (one order of magnitude lower than the total number of codes in the ADC). For a given architecture, the method provides the way to determine these levels to robustly capture the nonlinearity information. The location of each test level within the input range has low sensitivity to the internal ADC noise, and therefore, they are a good basis to continuously monitor the impact of process, aging and environment conditions variations (PVT) on the non-linearity, as well as miscalibration and possible failures in both foreground and background applications. The proposed method has been validated by realistic behavioral models in several examples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信