{"title":"用于气体绝缘开关系统状态监测的碳纳米管表面声波气体传感器","authors":"S. Umesh, K. Suma, T. Balachandra, A. Usha","doi":"10.1109/ERECT.2015.7499051","DOIUrl":null,"url":null,"abstract":"Sulfur hexafluoride (SF6) is the most common gas insulation medium used in a gas insulated switchgear (GIS) system. Though SF6 is a very good insulator, it is also a potential greenhouse gas having a global warming potential of 22 800 over a period of 100 years. Therefore its leakage to the environment should be strictly monitored. And also partial discharge or arcing in the SF6 filled switchgear chambers can reduce the life and quality of insulation and few of the constituent gases during partial discharge are toxic in nature. The early detection of partial discharge is necessary to prevent the quality degradation and failure of the system. Hence it becomes very essential to monitor the leakage and partial discharge detection regularly in a GIS. In this work, a simulation study has been carried out to detect SF6 leakage using carbon nanotube based MEMS/NEMS sensor which detects target gases at room temperature.","PeriodicalId":140556,"journal":{"name":"2015 International Conference on Emerging Research in Electronics, Computer Science and Technology (ICERECT)","volume":"438 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Carbon nanotube based Surface Acoustic Wave gas sensor for condition monitoring of gas insulated switchgear systems\",\"authors\":\"S. Umesh, K. Suma, T. Balachandra, A. Usha\",\"doi\":\"10.1109/ERECT.2015.7499051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sulfur hexafluoride (SF6) is the most common gas insulation medium used in a gas insulated switchgear (GIS) system. Though SF6 is a very good insulator, it is also a potential greenhouse gas having a global warming potential of 22 800 over a period of 100 years. Therefore its leakage to the environment should be strictly monitored. And also partial discharge or arcing in the SF6 filled switchgear chambers can reduce the life and quality of insulation and few of the constituent gases during partial discharge are toxic in nature. The early detection of partial discharge is necessary to prevent the quality degradation and failure of the system. Hence it becomes very essential to monitor the leakage and partial discharge detection regularly in a GIS. In this work, a simulation study has been carried out to detect SF6 leakage using carbon nanotube based MEMS/NEMS sensor which detects target gases at room temperature.\",\"PeriodicalId\":140556,\"journal\":{\"name\":\"2015 International Conference on Emerging Research in Electronics, Computer Science and Technology (ICERECT)\",\"volume\":\"438 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Emerging Research in Electronics, Computer Science and Technology (ICERECT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ERECT.2015.7499051\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Emerging Research in Electronics, Computer Science and Technology (ICERECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ERECT.2015.7499051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

六氟化硫(SF6)是气体绝缘开关设备(GIS)系统中最常用的气体绝缘介质。虽然SF6是一种非常好的绝缘体,但它也是一种潜在的温室气体,在100年的时间里,它的全球变暖潜能值为22800。因此,应严格监测其对环境的泄漏。在SF6填充的开关柜室中,局部放电或电弧会降低绝缘的寿命和质量,并且局部放电时产生的成分气体很少是有毒的。早期发现局部放电是防止系统质量下降和故障的必要措施。因此,在GIS系统中进行漏电监测和局部放电检测就显得十分必要。在这项工作中,利用基于碳纳米管的MEMS/NEMS传感器在室温下检测目标气体,进行了SF6泄漏的模拟研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Carbon nanotube based Surface Acoustic Wave gas sensor for condition monitoring of gas insulated switchgear systems
Sulfur hexafluoride (SF6) is the most common gas insulation medium used in a gas insulated switchgear (GIS) system. Though SF6 is a very good insulator, it is also a potential greenhouse gas having a global warming potential of 22 800 over a period of 100 years. Therefore its leakage to the environment should be strictly monitored. And also partial discharge or arcing in the SF6 filled switchgear chambers can reduce the life and quality of insulation and few of the constituent gases during partial discharge are toxic in nature. The early detection of partial discharge is necessary to prevent the quality degradation and failure of the system. Hence it becomes very essential to monitor the leakage and partial discharge detection regularly in a GIS. In this work, a simulation study has been carried out to detect SF6 leakage using carbon nanotube based MEMS/NEMS sensor which detects target gases at room temperature.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信