一个强大的陷波滤波器的PLI取消

Ali Mobaien, Arman Kheirati Roonizi, R. Boostani
{"title":"一个强大的陷波滤波器的PLI取消","authors":"Ali Mobaien, Arman Kheirati Roonizi, R. Boostani","doi":"10.1109/ICSPIS54653.2021.9729356","DOIUrl":null,"url":null,"abstract":"In this work, we present a powerful notch filter for power-line interference (PLI) cancelation from biomedical signals. This filter has a unit gain and a zero-phase response. Moreover, the filter can be implemented adaptively to adjust its bandwidth based on the signal-to-noise ratio. To realize this filter, a dynamic model is defined for PLI based on its sinusoid property. Then, a constrained least square error estimation is used to emerge the PLI based on the observations while the constraint is the PLI dynamic. At last, the estimated PLI is subtracted from recordings. The proposed filter is assessed using synthetic data and real biomedical recordings in different noise levels. The results demonstrate this filter as a very powerful and effective means for canceling the PLI out.","PeriodicalId":286966,"journal":{"name":"2021 7th International Conference on Signal Processing and Intelligent Systems (ICSPIS)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A powerful notch filter for PLI cancelation\",\"authors\":\"Ali Mobaien, Arman Kheirati Roonizi, R. Boostani\",\"doi\":\"10.1109/ICSPIS54653.2021.9729356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, we present a powerful notch filter for power-line interference (PLI) cancelation from biomedical signals. This filter has a unit gain and a zero-phase response. Moreover, the filter can be implemented adaptively to adjust its bandwidth based on the signal-to-noise ratio. To realize this filter, a dynamic model is defined for PLI based on its sinusoid property. Then, a constrained least square error estimation is used to emerge the PLI based on the observations while the constraint is the PLI dynamic. At last, the estimated PLI is subtracted from recordings. The proposed filter is assessed using synthetic data and real biomedical recordings in different noise levels. The results demonstrate this filter as a very powerful and effective means for canceling the PLI out.\",\"PeriodicalId\":286966,\"journal\":{\"name\":\"2021 7th International Conference on Signal Processing and Intelligent Systems (ICSPIS)\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 7th International Conference on Signal Processing and Intelligent Systems (ICSPIS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSPIS54653.2021.9729356\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 7th International Conference on Signal Processing and Intelligent Systems (ICSPIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSPIS54653.2021.9729356","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项工作中,我们提出了一个强大的陷波滤波器,用于消除生物医学信号中的电力线干扰(PLI)。该滤波器具有单位增益和零相位响应。此外,该滤波器可以根据信噪比自适应调整其带宽。为了实现该滤波器,根据PLI的正弦波特性定义了动态模型。然后,在约束为动态PLI的情况下,利用约束最小二乘误差估计得到基于观测值的PLI。最后,从录音中减去估计的PLI。使用合成数据和不同噪声水平下的真实生物医学记录对所提出的滤波器进行了评估。结果表明,该滤波器是一种非常强大和有效的消除PLI的手段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A powerful notch filter for PLI cancelation
In this work, we present a powerful notch filter for power-line interference (PLI) cancelation from biomedical signals. This filter has a unit gain and a zero-phase response. Moreover, the filter can be implemented adaptively to adjust its bandwidth based on the signal-to-noise ratio. To realize this filter, a dynamic model is defined for PLI based on its sinusoid property. Then, a constrained least square error estimation is used to emerge the PLI based on the observations while the constraint is the PLI dynamic. At last, the estimated PLI is subtracted from recordings. The proposed filter is assessed using synthetic data and real biomedical recordings in different noise levels. The results demonstrate this filter as a very powerful and effective means for canceling the PLI out.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信