变电站短路诊断与接地

T. Varodi, H. Balan, A. Pop, M. Buzdugan
{"title":"变电站短路诊断与接地","authors":"T. Varodi, H. Balan, A. Pop, M. Buzdugan","doi":"10.1109/ICATE.2014.6972613","DOIUrl":null,"url":null,"abstract":"The paper presents the monitoring of the power quality of an underground electric line fed by a high voltage transformer station 110/10 kV and a subsequent earthing fault situation followed by a short circuit. The monitoring process was performed using a power quality analyzer. The analysis of the evolution in time of the phenomena highlights the variations of the voltage in the medium voltage bus of the transformer station during the failure situation.","PeriodicalId":327050,"journal":{"name":"2014 International Conference on Applied and Theoretical Electricity (ICATE)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnosis of short circuit and the earthing of a transformer station\",\"authors\":\"T. Varodi, H. Balan, A. Pop, M. Buzdugan\",\"doi\":\"10.1109/ICATE.2014.6972613\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the monitoring of the power quality of an underground electric line fed by a high voltage transformer station 110/10 kV and a subsequent earthing fault situation followed by a short circuit. The monitoring process was performed using a power quality analyzer. The analysis of the evolution in time of the phenomena highlights the variations of the voltage in the medium voltage bus of the transformer station during the failure situation.\",\"PeriodicalId\":327050,\"journal\":{\"name\":\"2014 International Conference on Applied and Theoretical Electricity (ICATE)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Applied and Theoretical Electricity (ICATE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICATE.2014.6972613\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Applied and Theoretical Electricity (ICATE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICATE.2014.6972613","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了高压变电站110/ 10kv地下输电线的电能质量监测及接地故障后短路的情况。监测过程使用电能质量分析仪进行。通过对故障现象的时间演化分析,重点分析了故障发生时变电站中压母线电压的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnosis of short circuit and the earthing of a transformer station
The paper presents the monitoring of the power quality of an underground electric line fed by a high voltage transformer station 110/10 kV and a subsequent earthing fault situation followed by a short circuit. The monitoring process was performed using a power quality analyzer. The analysis of the evolution in time of the phenomena highlights the variations of the voltage in the medium voltage bus of the transformer station during the failure situation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信