{"title":"交流电压,电流和功率校准器","authors":"P. Miljanic","doi":"10.1109/CPEM.1988.671337","DOIUrl":null,"url":null,"abstract":"A computer-controlled calibrator capable of delivering AC sinusoidal and distorted voltage, current and power, with an accuracy of several parts per milion, is described. A combination of feedback and error-feedforward control strategy, together with the current comparator technique for very accurate ratio measurements, is implemented. The ppm stability of the calibrator permits the use of a multiplexing program for monitoring of several instruments over a long period of time.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Calibrator For Alternating Voltage, Current And Power\",\"authors\":\"P. Miljanic\",\"doi\":\"10.1109/CPEM.1988.671337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A computer-controlled calibrator capable of delivering AC sinusoidal and distorted voltage, current and power, with an accuracy of several parts per milion, is described. A combination of feedback and error-feedforward control strategy, together with the current comparator technique for very accurate ratio measurements, is implemented. The ppm stability of the calibrator permits the use of a multiplexing program for monitoring of several instruments over a long period of time.\",\"PeriodicalId\":326579,\"journal\":{\"name\":\"1988 Conference on Precision Electromagnetic Measurements\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1988 Conference on Precision Electromagnetic Measurements\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.1988.671337\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1988 Conference on Precision Electromagnetic Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.1988.671337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calibrator For Alternating Voltage, Current And Power
A computer-controlled calibrator capable of delivering AC sinusoidal and distorted voltage, current and power, with an accuracy of several parts per milion, is described. A combination of feedback and error-feedforward control strategy, together with the current comparator technique for very accurate ratio measurements, is implemented. The ppm stability of the calibrator permits the use of a multiplexing program for monitoring of several instruments over a long period of time.