电动汽车自动发电控制操作

P. M. Rocha Almeida, J. P. Peças Lopes, F. Soares, M. Vasconcelos
{"title":"电动汽车自动发电控制操作","authors":"P. M. Rocha Almeida, J. P. Peças Lopes, F. Soares, M. Vasconcelos","doi":"10.1109/IREP.2010.5563295","DOIUrl":null,"url":null,"abstract":"This paper presents a methodology to make EV able to contribute to secondary frequency regulation, by participating in Automatic Generation Control (AGC). The aggregator entity is used in this methodology to act as intermediate between the AGC and the EV controllers. The case-study used is an approximation of the Portuguese transmission/generation network, including existing tie lines with Spain, to which a solid three-phase short circuit was applied. After the disturbance, the impact of EV in the AGC operation was studied for two different situations: EV contributing to secondary frequency regulation and EV behaving as uncontrollable loads. The results obtained for both situations were then compared, in terms of interconnection active power flows in the existing tie-lines and its re-establishment time.","PeriodicalId":275834,"journal":{"name":"2010 IREP Symposium Bulk Power System Dynamics and Control - VIII (IREP)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":"{\"title\":\"Automatic Generation Control operation with electric vehicles\",\"authors\":\"P. M. Rocha Almeida, J. P. Peças Lopes, F. Soares, M. Vasconcelos\",\"doi\":\"10.1109/IREP.2010.5563295\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a methodology to make EV able to contribute to secondary frequency regulation, by participating in Automatic Generation Control (AGC). The aggregator entity is used in this methodology to act as intermediate between the AGC and the EV controllers. The case-study used is an approximation of the Portuguese transmission/generation network, including existing tie lines with Spain, to which a solid three-phase short circuit was applied. After the disturbance, the impact of EV in the AGC operation was studied for two different situations: EV contributing to secondary frequency regulation and EV behaving as uncontrollable loads. The results obtained for both situations were then compared, in terms of interconnection active power flows in the existing tie-lines and its re-establishment time.\",\"PeriodicalId\":275834,\"journal\":{\"name\":\"2010 IREP Symposium Bulk Power System Dynamics and Control - VIII (IREP)\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IREP Symposium Bulk Power System Dynamics and Control - VIII (IREP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IREP.2010.5563295\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IREP Symposium Bulk Power System Dynamics and Control - VIII (IREP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREP.2010.5563295","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

摘要

本文提出了一种通过参与自动发电控制(AGC),使电动汽车能够参与二次频率调节的方法。该方法使用聚合实体作为AGC和EV控制器之间的中介。所使用的案例研究近似于葡萄牙的输电/发电网络,包括与西班牙的现有联络线,其中采用了固体三相短路。扰动后,研究了电动汽车对AGC运行的影响,包括电动汽车作为二次频率调节和电动汽车作为不可控负载两种情况。然后比较了两种情况下的结果,即现有联络线的互联有功潮流及其重建时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic Generation Control operation with electric vehicles
This paper presents a methodology to make EV able to contribute to secondary frequency regulation, by participating in Automatic Generation Control (AGC). The aggregator entity is used in this methodology to act as intermediate between the AGC and the EV controllers. The case-study used is an approximation of the Portuguese transmission/generation network, including existing tie lines with Spain, to which a solid three-phase short circuit was applied. After the disturbance, the impact of EV in the AGC operation was studied for two different situations: EV contributing to secondary frequency regulation and EV behaving as uncontrollable loads. The results obtained for both situations were then compared, in terms of interconnection active power flows in the existing tie-lines and its re-establishment time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信