{"title":"离子污染和电压偏置下汽车温度下Cu-Al WB的可靠性评估","authors":"P. Lall, Sungmook Jung","doi":"10.1109/iTherm54085.2022.9899620","DOIUrl":null,"url":null,"abstract":"A deeper understanding of the acceleration factors under operating stresses is required for high-reliability harsh environment applications. Copper wire is now being used for first-level interconnects in automotive electronics. Palladium coated copper and gold-flash palladium coated copper are two copper wire compositions that have emerged. The corrosion resistance of copper wire bonds in high-temperature environments is still unknown. The EMC used to encapsulate chips and interconnects can vary widely in formulation, including pH, porosity, diffusion rate, composition of contaminants and contaminant concentration. A predictive model that can account for ambient factors, operational circumstances, and EMC exposure is required to accurately reflect projected wirebond dependability. Different EMCs were investigated in this work in a high-temperature-current environment with temperatures ranging from 60°C to 100°C and currents ranging from 0.2A to 1A. To build a Multiphysics model, diffusion kinetics based on the Nernst-Planck Equation for chlorine ion migration were combined with the Butler-Volmer equation for corrosion kinetics. Polarization curves for copper, aluminum, and intermetallics have been measured at various pH levels and chlorine-ion concentrations.Measurements of polarization curves were used to extract Tafel parameters.","PeriodicalId":351706,"journal":{"name":"2022 21st IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (iTherm)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability Assessment of Cu-Al WB under Automotive Temperatures in Presence of Ionic Contamination and Voltage Bias\",\"authors\":\"P. Lall, Sungmook Jung\",\"doi\":\"10.1109/iTherm54085.2022.9899620\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A deeper understanding of the acceleration factors under operating stresses is required for high-reliability harsh environment applications. Copper wire is now being used for first-level interconnects in automotive electronics. Palladium coated copper and gold-flash palladium coated copper are two copper wire compositions that have emerged. The corrosion resistance of copper wire bonds in high-temperature environments is still unknown. The EMC used to encapsulate chips and interconnects can vary widely in formulation, including pH, porosity, diffusion rate, composition of contaminants and contaminant concentration. A predictive model that can account for ambient factors, operational circumstances, and EMC exposure is required to accurately reflect projected wirebond dependability. Different EMCs were investigated in this work in a high-temperature-current environment with temperatures ranging from 60°C to 100°C and currents ranging from 0.2A to 1A. To build a Multiphysics model, diffusion kinetics based on the Nernst-Planck Equation for chlorine ion migration were combined with the Butler-Volmer equation for corrosion kinetics. Polarization curves for copper, aluminum, and intermetallics have been measured at various pH levels and chlorine-ion concentrations.Measurements of polarization curves were used to extract Tafel parameters.\",\"PeriodicalId\":351706,\"journal\":{\"name\":\"2022 21st IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (iTherm)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 21st IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (iTherm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iTherm54085.2022.9899620\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 21st IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (iTherm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iTherm54085.2022.9899620","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reliability Assessment of Cu-Al WB under Automotive Temperatures in Presence of Ionic Contamination and Voltage Bias
A deeper understanding of the acceleration factors under operating stresses is required for high-reliability harsh environment applications. Copper wire is now being used for first-level interconnects in automotive electronics. Palladium coated copper and gold-flash palladium coated copper are two copper wire compositions that have emerged. The corrosion resistance of copper wire bonds in high-temperature environments is still unknown. The EMC used to encapsulate chips and interconnects can vary widely in formulation, including pH, porosity, diffusion rate, composition of contaminants and contaminant concentration. A predictive model that can account for ambient factors, operational circumstances, and EMC exposure is required to accurately reflect projected wirebond dependability. Different EMCs were investigated in this work in a high-temperature-current environment with temperatures ranging from 60°C to 100°C and currents ranging from 0.2A to 1A. To build a Multiphysics model, diffusion kinetics based on the Nernst-Planck Equation for chlorine ion migration were combined with the Butler-Volmer equation for corrosion kinetics. Polarization curves for copper, aluminum, and intermetallics have been measured at various pH levels and chlorine-ion concentrations.Measurements of polarization curves were used to extract Tafel parameters.