两种三维位置敏感CZT探测器用于小动物PET的可行性研究

Feng Zhang, Zhong He, Dan Xu, Ling-Jian Meng
{"title":"两种三维位置敏感CZT探测器用于小动物PET的可行性研究","authors":"Feng Zhang, Zhong He, Dan Xu, Ling-Jian Meng","doi":"10.1109/NSSMIC.2005.1596621","DOIUrl":null,"url":null,"abstract":"An experimental small animal PET using two 3-D position sensitive CdZnTe detectors was developed and tested. Each 1.5/spl times/1.5/spl times/1 cm/sup 3/ CdZnTe detector employs 11 by 11 pixellated anodes wire-bonded to the VAS3.1/TAT3/MCR3 readout electronics. Each detector can obtain the deposited energy and 3-D coordinates for single-pixel and multiple-pixel events. Both systems achieved energy resolutions of better than 1.0% FWHM at 662 ReV for single-pixel events and better than 1.5% FWHM at 662 ReV for two-pixel events. The position resolution of each detector was estimated to be /spl sim/1.3/spl times/1.3/spl times/0.5 mm/sup 3/. Modifications to the firmware of the readout board and additions of custom-built circuitry enabled coincidence measurement between two 3-D CdZnTe detector systems using VAS3.1/TAT3/MCR3 readout systems. Spatial resolution improvements by using depth of interaction (DOI) and by identifying the first interaction using Compton scattering angle reconstruction are reported and discussed.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Feasibility study of using two 3-D position sensitive CZT detectors for small animal PET\",\"authors\":\"Feng Zhang, Zhong He, Dan Xu, Ling-Jian Meng\",\"doi\":\"10.1109/NSSMIC.2005.1596621\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An experimental small animal PET using two 3-D position sensitive CdZnTe detectors was developed and tested. Each 1.5/spl times/1.5/spl times/1 cm/sup 3/ CdZnTe detector employs 11 by 11 pixellated anodes wire-bonded to the VAS3.1/TAT3/MCR3 readout electronics. Each detector can obtain the deposited energy and 3-D coordinates for single-pixel and multiple-pixel events. Both systems achieved energy resolutions of better than 1.0% FWHM at 662 ReV for single-pixel events and better than 1.5% FWHM at 662 ReV for two-pixel events. The position resolution of each detector was estimated to be /spl sim/1.3/spl times/1.3/spl times/0.5 mm/sup 3/. Modifications to the firmware of the readout board and additions of custom-built circuitry enabled coincidence measurement between two 3-D CdZnTe detector systems using VAS3.1/TAT3/MCR3 readout systems. Spatial resolution improvements by using depth of interaction (DOI) and by identifying the first interaction using Compton scattering angle reconstruction are reported and discussed.\",\"PeriodicalId\":105619,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2005.1596621\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

研制并测试了一种使用两个三维位置敏感CdZnTe探测器的实验性小动物PET。每个1.5/spl倍/1.5/spl倍/1 cm/sup / CdZnTe探测器采用11 × 11像素化阳极线接到VAS3.1/TAT3/MCR3读出电子器件。每个探测器都可以获得单像素和多像素事件的沉积能量和三维坐标。对于单像素事件,两种系统在662 ReV下的能量分辨率均优于1.0% FWHM,对于双像素事件,在662 ReV下的能量分辨率均优于1.5% FWHM。每个探测器的位置分辨率估计为/spl sim/1.3/spl times/1.3/spl times/0.5 mm/sup 3/。对读出板固件的修改和定制电路的增加使使用VAS3.1/TAT3/MCR3读出系统的两个3-D CdZnTe探测器系统之间的一致性测量成为可能。本文报道并讨论了利用相互作用深度(DOI)和利用康普顿散射角重建识别第一相互作用来提高空间分辨率的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feasibility study of using two 3-D position sensitive CZT detectors for small animal PET
An experimental small animal PET using two 3-D position sensitive CdZnTe detectors was developed and tested. Each 1.5/spl times/1.5/spl times/1 cm/sup 3/ CdZnTe detector employs 11 by 11 pixellated anodes wire-bonded to the VAS3.1/TAT3/MCR3 readout electronics. Each detector can obtain the deposited energy and 3-D coordinates for single-pixel and multiple-pixel events. Both systems achieved energy resolutions of better than 1.0% FWHM at 662 ReV for single-pixel events and better than 1.5% FWHM at 662 ReV for two-pixel events. The position resolution of each detector was estimated to be /spl sim/1.3/spl times/1.3/spl times/0.5 mm/sup 3/. Modifications to the firmware of the readout board and additions of custom-built circuitry enabled coincidence measurement between two 3-D CdZnTe detector systems using VAS3.1/TAT3/MCR3 readout systems. Spatial resolution improvements by using depth of interaction (DOI) and by identifying the first interaction using Compton scattering angle reconstruction are reported and discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信