Marina De Godoy Almeida, Mariângela Salles Pereira Nassar, C. Bataglion, F. V. de Mello Filho, Alexandre Laguna Terreri, C. Bataglion
{"title":"脸弓与一种基于水平仪的新技术的可重复性比较","authors":"Marina De Godoy Almeida, Mariângela Salles Pereira Nassar, C. Bataglion, F. V. de Mello Filho, Alexandre Laguna Terreri, C. Bataglion","doi":"10.1080/08869634.2019.1650214","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objective: This study aimed to introduce a spirit level device for mounting maxillary casts to compare the reproducibility between the facebow and this new technique. Methods: The maxillary casts of 10 participants were mounted in three different situations: 1) with the facebow; 2) with the spirit level device, the participant in seated position; and 3) with the spirit level device with participant in standing position. Each procedure was performed by three different evaluators. The values obtained were calculated using the Technical Error of Measurement (TEM) and the inter-evaluator Coefficient of Variation (CV). Results: The mean values obtained were 4.3 mm, 2.2 mm, and 2.6 mm for absolute TEM; 8.7%, 5.4%, and 6.4% for relative TEM; and 7.3%, 4.5%, and 5.6% for CV. Conclusion: These results show that the facebow is less reproducible compared to the new device, demonstrating that the new technique can be satisfactorily used in clinical practice.","PeriodicalId":162405,"journal":{"name":"CRANIO®","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison reproducibility between the facebow and a new technique based on a spirit level device\",\"authors\":\"Marina De Godoy Almeida, Mariângela Salles Pereira Nassar, C. Bataglion, F. V. de Mello Filho, Alexandre Laguna Terreri, C. Bataglion\",\"doi\":\"10.1080/08869634.2019.1650214\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Objective: This study aimed to introduce a spirit level device for mounting maxillary casts to compare the reproducibility between the facebow and this new technique. Methods: The maxillary casts of 10 participants were mounted in three different situations: 1) with the facebow; 2) with the spirit level device, the participant in seated position; and 3) with the spirit level device with participant in standing position. Each procedure was performed by three different evaluators. The values obtained were calculated using the Technical Error of Measurement (TEM) and the inter-evaluator Coefficient of Variation (CV). Results: The mean values obtained were 4.3 mm, 2.2 mm, and 2.6 mm for absolute TEM; 8.7%, 5.4%, and 6.4% for relative TEM; and 7.3%, 4.5%, and 5.6% for CV. Conclusion: These results show that the facebow is less reproducible compared to the new device, demonstrating that the new technique can be satisfactorily used in clinical practice.\",\"PeriodicalId\":162405,\"journal\":{\"name\":\"CRANIO®\",\"volume\":\"59 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CRANIO®\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08869634.2019.1650214\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CRANIO®","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08869634.2019.1650214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
摘要目的:本研究旨在介绍一种用于上颌铸造固定的水平仪,比较脸弓与这种新技术的可重复性。方法:对10名上颌患者分别在三种不同的情况下进行上牙模的固定:1)面弓固定;2)配合水平仪,参与者处于坐位;3)与受试者站姿配合的水平仪。每个程序由三个不同的评估人员执行。采用技术测量误差(Technical Error of Measurement, TEM)和评价者间变异系数(interevaluator Coefficient of Variation, CV)计算所得值。结果:TEM绝对值平均值分别为4.3 mm、2.2 mm、2.6 mm;相对TEM为8.7%、5.4%、6.4%;CV分别为7.3%、4.5%和5.6%。结论:与新器械相比,脸弓的可重复性较低,表明新技术可令人满意地应用于临床。
Comparison reproducibility between the facebow and a new technique based on a spirit level device
ABSTRACT Objective: This study aimed to introduce a spirit level device for mounting maxillary casts to compare the reproducibility between the facebow and this new technique. Methods: The maxillary casts of 10 participants were mounted in three different situations: 1) with the facebow; 2) with the spirit level device, the participant in seated position; and 3) with the spirit level device with participant in standing position. Each procedure was performed by three different evaluators. The values obtained were calculated using the Technical Error of Measurement (TEM) and the inter-evaluator Coefficient of Variation (CV). Results: The mean values obtained were 4.3 mm, 2.2 mm, and 2.6 mm for absolute TEM; 8.7%, 5.4%, and 6.4% for relative TEM; and 7.3%, 4.5%, and 5.6% for CV. Conclusion: These results show that the facebow is less reproducible compared to the new device, demonstrating that the new technique can be satisfactorily used in clinical practice.