P. Sahu
{"title":"12区两网火电同步不同联络线的性能分析","authors":"P. Sahu","doi":"10.51983/ajes-2017.6.2.1997","DOIUrl":null,"url":null,"abstract":"This paper represents the advantages of HVAC-HVDC parallel tie-line as compare to the Flexible AC Transmission System (FACTS) tie-line and normal HVAC tie-line for synchronization of 12-area two interconnected thermal power grid with its all 12 areas when load changed in power grid-1 (area-6). After load change in power grid-1 (area-6), 12-area two interconnected thermal power grid with its all 12 areas are synchronized at the same time only in case of HVAC-HVDC parallel tie-line. This paper also shows the Flexible AC Transmission System (FACTS) tie-line is better as compare to the normal HVAC tie-line. Performance analysis of different tie-line for synchronization or load (machine) frequency control of 12-area two interconnected thermal power grid is done in terms of settling time of frequency deviation of all 12 areas and settling time of tie-line power deviation of two interconnected areas or two interconnected power grid by using conventional integral controller when load changed in power grid-1 (area-6).","PeriodicalId":365290,"journal":{"name":"Asian Journal of Electrical Sciences","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Analysis of Different Tie-Line for Synchronization of 12-Area Two Interconnected Thermal Power Grid\",\"authors\":\"P. Sahu\",\"doi\":\"10.51983/ajes-2017.6.2.1997\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper represents the advantages of HVAC-HVDC parallel tie-line as compare to the Flexible AC Transmission System (FACTS) tie-line and normal HVAC tie-line for synchronization of 12-area two interconnected thermal power grid with its all 12 areas when load changed in power grid-1 (area-6). After load change in power grid-1 (area-6), 12-area two interconnected thermal power grid with its all 12 areas are synchronized at the same time only in case of HVAC-HVDC parallel tie-line. This paper also shows the Flexible AC Transmission System (FACTS) tie-line is better as compare to the normal HVAC tie-line. Performance analysis of different tie-line for synchronization or load (machine) frequency control of 12-area two interconnected thermal power grid is done in terms of settling time of frequency deviation of all 12 areas and settling time of tie-line power deviation of two interconnected areas or two interconnected power grid by using conventional integral controller when load changed in power grid-1 (area-6).\",\"PeriodicalId\":365290,\"journal\":{\"name\":\"Asian Journal of Electrical Sciences\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Electrical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51983/ajes-2017.6.2.1997\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Electrical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51983/ajes-2017.6.2.1997","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了在1号网(6号网)负荷变化时,采用HVAC- hvdc并联联络线实现12区两互联火电网全部12区同步的优势,并与柔性交流输电系统(FACTS)联络线和普通HVAC联络线进行了比较。1号网(6区)负荷变化后,只有在交直流并联的情况下,12区两互联火电网的全部12区同时同步。本文还论证了柔性交流输电系统(FACTS)联络线与普通暖通空调联络线的优越性。利用常规积分控制器在1网(6区)负荷变化时,对12区两互联火网同步或负荷(机)频控制不同联络线的性能进行了分析,包括所有12区频率偏差的沉降时间和两互联区或两互联电网的联络线功率偏差的沉降时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Analysis of Different Tie-Line for Synchronization of 12-Area Two Interconnected Thermal Power Grid
This paper represents the advantages of HVAC-HVDC parallel tie-line as compare to the Flexible AC Transmission System (FACTS) tie-line and normal HVAC tie-line for synchronization of 12-area two interconnected thermal power grid with its all 12 areas when load changed in power grid-1 (area-6). After load change in power grid-1 (area-6), 12-area two interconnected thermal power grid with its all 12 areas are synchronized at the same time only in case of HVAC-HVDC parallel tie-line. This paper also shows the Flexible AC Transmission System (FACTS) tie-line is better as compare to the normal HVAC tie-line. Performance analysis of different tie-line for synchronization or load (machine) frequency control of 12-area two interconnected thermal power grid is done in terms of settling time of frequency deviation of all 12 areas and settling time of tie-line power deviation of two interconnected areas or two interconnected power grid by using conventional integral controller when load changed in power grid-1 (area-6).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信