{"title":"光学透明头戴式显示器校准程序的评价","authors":"Arthur Tang, Ji Zhou, C. Owen","doi":"10.1109/ISMAR.2003.1240699","DOIUrl":null,"url":null,"abstract":"Optical see-through head-mounted displays (HMDs) are less commonly used because they are difficult to accurately calibrate. In this article, we report a user study to compare the accuracy of 4 variants of the SPAAM calibration method. Among the 4 variants, Stylus-marker calibration, where the user aligns a crosshair projected in the HMD with a tracked stylus tip, achieved the most accurate result. A decomposition and analysis of the calibration matrices from the trials is performed and the characteristics of the computed calibration matrices are examined. A physiological engineering point of view is also discussed to explain why calibrating optical see-through HMD is so difficult for users.","PeriodicalId":296266,"journal":{"name":"The Second IEEE and ACM International Symposium on Mixed and Augmented Reality, 2003. Proceedings.","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":"{\"title\":\"Evaluation of calibration procedures for optical see-through head-mounted displays\",\"authors\":\"Arthur Tang, Ji Zhou, C. Owen\",\"doi\":\"10.1109/ISMAR.2003.1240699\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optical see-through head-mounted displays (HMDs) are less commonly used because they are difficult to accurately calibrate. In this article, we report a user study to compare the accuracy of 4 variants of the SPAAM calibration method. Among the 4 variants, Stylus-marker calibration, where the user aligns a crosshair projected in the HMD with a tracked stylus tip, achieved the most accurate result. A decomposition and analysis of the calibration matrices from the trials is performed and the characteristics of the computed calibration matrices are examined. A physiological engineering point of view is also discussed to explain why calibrating optical see-through HMD is so difficult for users.\",\"PeriodicalId\":296266,\"journal\":{\"name\":\"The Second IEEE and ACM International Symposium on Mixed and Augmented Reality, 2003. Proceedings.\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"47\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Second IEEE and ACM International Symposium on Mixed and Augmented Reality, 2003. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISMAR.2003.1240699\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Second IEEE and ACM International Symposium on Mixed and Augmented Reality, 2003. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMAR.2003.1240699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of calibration procedures for optical see-through head-mounted displays
Optical see-through head-mounted displays (HMDs) are less commonly used because they are difficult to accurately calibrate. In this article, we report a user study to compare the accuracy of 4 variants of the SPAAM calibration method. Among the 4 variants, Stylus-marker calibration, where the user aligns a crosshair projected in the HMD with a tracked stylus tip, achieved the most accurate result. A decomposition and analysis of the calibration matrices from the trials is performed and the characteristics of the computed calibration matrices are examined. A physiological engineering point of view is also discussed to explain why calibrating optical see-through HMD is so difficult for users.