SenseBack -植入式神经刺激和记录装置的植入考虑

I. Williams, Adrien Rapeaux, Jack Pearson, K. Nazarpour, E. Brunton, Song Luan, Yan Liu, T. Constandinou
{"title":"SenseBack -植入式神经刺激和记录装置的植入考虑","authors":"I. Williams, Adrien Rapeaux, Jack Pearson, K. Nazarpour, E. Brunton, Song Luan, Yan Liu, T. Constandinou","doi":"10.1109/BIOCAS.2019.8919046","DOIUrl":null,"url":null,"abstract":"This paper describes a fully implantable and highly compact neural interface platform for chronic (> 6 month) rat and small rodent experiments. It provides 32 channels of highly flexible neural stimulation and recording with wireless control and data readout, as well as wireless transcutaneous power (although power waste remains a challenge). All the system firmware is fully upgradeable over the air (even after implantation) allowing future enhancements such as closed loop operation or data filtering. This paper focuses on the implant considerations – i.e. design and manufacture of the physical platform, encapsulation, wireless connections and testing.","PeriodicalId":222264,"journal":{"name":"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"SenseBack – Implant considerations for an implantable neural stimulation and recording device\",\"authors\":\"I. Williams, Adrien Rapeaux, Jack Pearson, K. Nazarpour, E. Brunton, Song Luan, Yan Liu, T. Constandinou\",\"doi\":\"10.1109/BIOCAS.2019.8919046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a fully implantable and highly compact neural interface platform for chronic (> 6 month) rat and small rodent experiments. It provides 32 channels of highly flexible neural stimulation and recording with wireless control and data readout, as well as wireless transcutaneous power (although power waste remains a challenge). All the system firmware is fully upgradeable over the air (even after implantation) allowing future enhancements such as closed loop operation or data filtering. This paper focuses on the implant considerations – i.e. design and manufacture of the physical platform, encapsulation, wireless connections and testing.\",\"PeriodicalId\":222264,\"journal\":{\"name\":\"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2019.8919046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2019.8919046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文介绍了一种用于慢性(> 6个月)大鼠和小型啮齿动物实验的完全植入式和高度紧凑的神经接口平台。它提供32个高度灵活的神经刺激通道,并通过无线控制和数据读出进行记录,以及无线经皮供电(尽管电力浪费仍然是一个挑战)。所有的系统固件都可以通过空气完全升级(即使在植入之后),允许未来的增强,如闭环操作或数据过滤。本文重点介绍了植入物的考虑因素,即物理平台的设计和制造、封装、无线连接和测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SenseBack – Implant considerations for an implantable neural stimulation and recording device
This paper describes a fully implantable and highly compact neural interface platform for chronic (> 6 month) rat and small rodent experiments. It provides 32 channels of highly flexible neural stimulation and recording with wireless control and data readout, as well as wireless transcutaneous power (although power waste remains a challenge). All the system firmware is fully upgradeable over the air (even after implantation) allowing future enhancements such as closed loop operation or data filtering. This paper focuses on the implant considerations – i.e. design and manufacture of the physical platform, encapsulation, wireless connections and testing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信