脊柱侧弯手术后,胸椎椎弓根螺钉在主动脉附近意外定位

Ali Murat Başak, T. Ege, E. Yildirim, Ömer Levent Karadamar, D. Çankaya
{"title":"脊柱侧弯手术后,胸椎椎弓根螺钉在主动脉附近意外定位","authors":"Ali Murat Başak, T. Ege, E. Yildirim, Ömer Levent Karadamar, D. Çankaya","doi":"10.52312/jdrscr.2022.94","DOIUrl":null,"url":null,"abstract":"The pedicle is the structure that connects the anterior column with the middle and posterior column. Because the pedicle screw passes through the vertebral pedicle and extends to the anterior column, it is a solid stabilization technique that covers all three columns and a method that has a wide range of use from spinal deformity to degenerative spine and tumors.[1] Since the screw also passes through the inner column, the surrounding structures are at risk. The most important of these structures is the spinal cord. The thoracic region, particularly the azygos vein, intercostal artery, inferior vena cava, and aorta, and the iliac arteries in the lumbar region are at risk. Vascular injuries are a rare but substantial complication of spinal surgery.[2]","PeriodicalId":196868,"journal":{"name":"Joint Diseases and Related Surgery Case Reports","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unexpected localization of a thoracic pedicle screw nearby the aorta after scoliosis surgery\",\"authors\":\"Ali Murat Başak, T. Ege, E. Yildirim, Ömer Levent Karadamar, D. Çankaya\",\"doi\":\"10.52312/jdrscr.2022.94\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The pedicle is the structure that connects the anterior column with the middle and posterior column. Because the pedicle screw passes through the vertebral pedicle and extends to the anterior column, it is a solid stabilization technique that covers all three columns and a method that has a wide range of use from spinal deformity to degenerative spine and tumors.[1] Since the screw also passes through the inner column, the surrounding structures are at risk. The most important of these structures is the spinal cord. The thoracic region, particularly the azygos vein, intercostal artery, inferior vena cava, and aorta, and the iliac arteries in the lumbar region are at risk. Vascular injuries are a rare but substantial complication of spinal surgery.[2]\",\"PeriodicalId\":196868,\"journal\":{\"name\":\"Joint Diseases and Related Surgery Case Reports\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Joint Diseases and Related Surgery Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52312/jdrscr.2022.94\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Joint Diseases and Related Surgery Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52312/jdrscr.2022.94","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

椎弓根是连接前柱、中柱和后柱的结构。由于椎弓根螺钉穿过椎弓根并延伸至前柱,是一种覆盖所有三柱的坚固稳定技术,是一种从脊柱畸形到退行性脊柱和肿瘤的广泛应用方法。[1]由于螺钉也穿过内柱,因此周围的结构处于危险之中。这些结构中最重要的是脊髓。胸椎部位,尤其是奇静脉、肋间动脉、下腔静脉、主动脉和腰椎部位的髂动脉是危险的。血管损伤是脊柱手术中一种罕见但重要的并发症。[2]
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Unexpected localization of a thoracic pedicle screw nearby the aorta after scoliosis surgery
The pedicle is the structure that connects the anterior column with the middle and posterior column. Because the pedicle screw passes through the vertebral pedicle and extends to the anterior column, it is a solid stabilization technique that covers all three columns and a method that has a wide range of use from spinal deformity to degenerative spine and tumors.[1] Since the screw also passes through the inner column, the surrounding structures are at risk. The most important of these structures is the spinal cord. The thoracic region, particularly the azygos vein, intercostal artery, inferior vena cava, and aorta, and the iliac arteries in the lumbar region are at risk. Vascular injuries are a rare but substantial complication of spinal surgery.[2]
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信