{"title":"用多通道分析仪测量技术设备的传输时间","authors":"H.-H. Deicke, J. Flachowsky, K.-P. Rudolph, N. Beiermann","doi":"10.1080/10256018508623433","DOIUrl":null,"url":null,"abstract":"The radioactive tracer technique is a possible means of obtaining flow rates. The principle is very simple: 113m In labelled single grains will be injected upstream into the flow individually at determined sequences of time. Its transit time between two positions of a known distance is measured, generally using scintillations detectors coupled with a special limit value switch, controling a short time meter in the first case. In the other case or simultaneously a multichannel analyser (NTA-1024) in multiscaling mode online coupled with a programmable calculator (EMG-666) was used. In this way it is possible to measure transit times 5 m/s. The relative error of this measurement is less than 1%. The measuring system and some experimental results are represented.","PeriodicalId":296380,"journal":{"name":"Februar 1985","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Transit Time Measurements in Technical Plants by Using a Multichannel Analyser\",\"authors\":\"H.-H. Deicke, J. Flachowsky, K.-P. Rudolph, N. Beiermann\",\"doi\":\"10.1080/10256018508623433\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The radioactive tracer technique is a possible means of obtaining flow rates. The principle is very simple: 113m In labelled single grains will be injected upstream into the flow individually at determined sequences of time. Its transit time between two positions of a known distance is measured, generally using scintillations detectors coupled with a special limit value switch, controling a short time meter in the first case. In the other case or simultaneously a multichannel analyser (NTA-1024) in multiscaling mode online coupled with a programmable calculator (EMG-666) was used. In this way it is possible to measure transit times 5 m/s. The relative error of this measurement is less than 1%. The measuring system and some experimental results are represented.\",\"PeriodicalId\":296380,\"journal\":{\"name\":\"Februar 1985\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Februar 1985\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10256018508623433\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Februar 1985","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10256018508623433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

放射性示踪技术是获得流速的一种可能手段。原理非常简单:在确定的时间序列中,113m的标记的单个颗粒将被单独注入上游的流动中。测量其在已知距离的两个位置之间的传递时间,通常使用闪烁探测器加上一个特殊的限值开关,在第一种情况下控制一个短时间计。在另一种情况下,或同时使用多刻度模式的多通道分析仪(NTA-1024)与可编程计算器(肌电图-666)在线耦合。用这种方法可以测量5米/秒的凌日时间。该测量的相对误差小于1%。介绍了测量系统和一些实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transit Time Measurements in Technical Plants by Using a Multichannel Analyser
The radioactive tracer technique is a possible means of obtaining flow rates. The principle is very simple: 113m In labelled single grains will be injected upstream into the flow individually at determined sequences of time. Its transit time between two positions of a known distance is measured, generally using scintillations detectors coupled with a special limit value switch, controling a short time meter in the first case. In the other case or simultaneously a multichannel analyser (NTA-1024) in multiscaling mode online coupled with a programmable calculator (EMG-666) was used. In this way it is possible to measure transit times 5 m/s. The relative error of this measurement is less than 1%. The measuring system and some experimental results are represented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信