Mehmet Akif Özçoban, F. Latifoğlu, A. Ülgen, M. H. Asyali
{"title":"用介电渗透率法监测水体交换","authors":"Mehmet Akif Özçoban, F. Latifoğlu, A. Ülgen, M. H. Asyali","doi":"10.1109/BIYOMUT.2010.5479836","DOIUrl":null,"url":null,"abstract":"Bioelectric impedance analysis (BIA) is a widely technique in determining body composition. In this method, two electrodes are placed at suitable points on the body and alternating current at different frequencies are passed through those points. Then, the voltage difference between the two points is measured and corresponding bioelectric impedance is calculated. In this study, BIA measurement calculated with dielectric permeability technique. This method differs from the conventional BIA in that, the measurement is totally noninvasive. In future studies, we will apply the proposed method in determining the amount of total body water and weight ratio of dry body mass for hemodialysis patients.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring the body water exchange using dielectric permeability method\",\"authors\":\"Mehmet Akif Özçoban, F. Latifoğlu, A. Ülgen, M. H. Asyali\",\"doi\":\"10.1109/BIYOMUT.2010.5479836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bioelectric impedance analysis (BIA) is a widely technique in determining body composition. In this method, two electrodes are placed at suitable points on the body and alternating current at different frequencies are passed through those points. Then, the voltage difference between the two points is measured and corresponding bioelectric impedance is calculated. In this study, BIA measurement calculated with dielectric permeability technique. This method differs from the conventional BIA in that, the measurement is totally noninvasive. In future studies, we will apply the proposed method in determining the amount of total body water and weight ratio of dry body mass for hemodialysis patients.\",\"PeriodicalId\":180275,\"journal\":{\"name\":\"2010 15th National Biomedical Engineering Meeting\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 15th National Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIYOMUT.2010.5479836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 15th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2010.5479836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Monitoring the body water exchange using dielectric permeability method
Bioelectric impedance analysis (BIA) is a widely technique in determining body composition. In this method, two electrodes are placed at suitable points on the body and alternating current at different frequencies are passed through those points. Then, the voltage difference between the two points is measured and corresponding bioelectric impedance is calculated. In this study, BIA measurement calculated with dielectric permeability technique. This method differs from the conventional BIA in that, the measurement is totally noninvasive. In future studies, we will apply the proposed method in determining the amount of total body water and weight ratio of dry body mass for hemodialysis patients.