用于偏远地区制冷的独立光伏系统:埃及的技术经济案例研究。

Nourhan Alaa El-Din, W. Anis, Adel Ahmed, S. Abdellatif
{"title":"用于偏远地区制冷的独立光伏系统:埃及的技术经济案例研究。","authors":"Nourhan Alaa El-Din, W. Anis, Adel Ahmed, S. Abdellatif","doi":"10.1109/CPERE56564.2023.10119596","DOIUrl":null,"url":null,"abstract":"This paper considers the optimum design of a standalone photovoltaic (PV) system to drive a refrigerator located in a remote (off-grid) area. The optimality criterion is to obtain a design with a minimum cost of generated kWh. The cost parameters affect the PV array size and the battery storage size. It is shown that as PV array size increases, the battery size decreases to a specific limit. The optimum design should satisfy the condition that the State of Charge (SOC) of the Battery on January 1 is the same as at the end of December 31. This means that the Battery stored charge remains constant at the end of the year, i.e., the PV system supplies the load energy. This research concentrates on the effect of battery storage systems on both system reliability and system cost. Based on a developed simulation program, the results obtained in this research showed that the cost of kWh generated remains low till 99.3% reliability. Any increase of reliability over 99.3% increases the cost significantly.","PeriodicalId":169048,"journal":{"name":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stand-alone PV System For Remote Area Refrigeration: Techno-economic Case Study in Egypt.\",\"authors\":\"Nourhan Alaa El-Din, W. Anis, Adel Ahmed, S. Abdellatif\",\"doi\":\"10.1109/CPERE56564.2023.10119596\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper considers the optimum design of a standalone photovoltaic (PV) system to drive a refrigerator located in a remote (off-grid) area. The optimality criterion is to obtain a design with a minimum cost of generated kWh. The cost parameters affect the PV array size and the battery storage size. It is shown that as PV array size increases, the battery size decreases to a specific limit. The optimum design should satisfy the condition that the State of Charge (SOC) of the Battery on January 1 is the same as at the end of December 31. This means that the Battery stored charge remains constant at the end of the year, i.e., the PV system supplies the load energy. This research concentrates on the effect of battery storage systems on both system reliability and system cost. Based on a developed simulation program, the results obtained in this research showed that the cost of kWh generated remains low till 99.3% reliability. Any increase of reliability over 99.3% increases the cost significantly.\",\"PeriodicalId\":169048,\"journal\":{\"name\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPERE56564.2023.10119596\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPERE56564.2023.10119596","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了一个独立的光伏(PV)系统的优化设计,以驱动偏远(离网)地区的冰箱。最优性准则是获得具有最小发电千瓦时成本的设计。成本参数影响光伏阵列尺寸和电池存储尺寸。结果表明,随着光伏阵列尺寸的增大,电池尺寸减小到一定的极限。优化设计应满足电池1月1日与12月31日的荷电状态(SOC)相同的条件。这意味着电池存储的电量在年底保持不变,即光伏系统提供负载能量。本文主要研究电池储能系统对系统可靠性和系统成本的影响。基于开发的仿真程序,本研究得到的结果表明,在99.3%的可靠性下,发电千瓦时的成本仍然很低。可靠性提高99.3%以上,成本就会显著增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stand-alone PV System For Remote Area Refrigeration: Techno-economic Case Study in Egypt.
This paper considers the optimum design of a standalone photovoltaic (PV) system to drive a refrigerator located in a remote (off-grid) area. The optimality criterion is to obtain a design with a minimum cost of generated kWh. The cost parameters affect the PV array size and the battery storage size. It is shown that as PV array size increases, the battery size decreases to a specific limit. The optimum design should satisfy the condition that the State of Charge (SOC) of the Battery on January 1 is the same as at the end of December 31. This means that the Battery stored charge remains constant at the end of the year, i.e., the PV system supplies the load energy. This research concentrates on the effect of battery storage systems on both system reliability and system cost. Based on a developed simulation program, the results obtained in this research showed that the cost of kWh generated remains low till 99.3% reliability. Any increase of reliability over 99.3% increases the cost significantly.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信