{"title":"基于多重光容积脉搏波特征的连续血压监测方法","authors":"Yang Xu, Zhipei Huang, Jiankang Wu, Zhongdi Liu","doi":"10.3233/atde210246","DOIUrl":null,"url":null,"abstract":"Continuous blood pressure monitoring is of great significance for the prevention and early diagnosis of cardiovascular diseases. However, the existing continuous blood pressure monitoring methods, especially the sleeveless blood pressure monitoring methods, are complex and computationally heavy. In this paper, we propose a method, using plethysmography (PPG) signals alone, to estimate continuous blood pressure by extracting multiple PPG features related to intravascular blood flow characteristics. The performance of our method was evaluated using ten minutes synchronized PPG signals and continuous blood pressure from 21 healthy volunteers and 19 patients with hypertension and diabetes. The test results have shown that the absolute mean errors and standard deviation errors between the estimated and referenced blood pressure are 3.22±0.66 mmHg for systolic blood pressure and 2.11±1.11 mmHg for diastolic blood pressure, which meet AAMI (the association for the advancement of medical instrumentation) error acceptance.","PeriodicalId":386877,"journal":{"name":"Computer Methods in Medicine and Health Care","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Continuous Blood Pressure Monitoring Method Based on Multiple Photoplethysmography Features\",\"authors\":\"Yang Xu, Zhipei Huang, Jiankang Wu, Zhongdi Liu\",\"doi\":\"10.3233/atde210246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Continuous blood pressure monitoring is of great significance for the prevention and early diagnosis of cardiovascular diseases. However, the existing continuous blood pressure monitoring methods, especially the sleeveless blood pressure monitoring methods, are complex and computationally heavy. In this paper, we propose a method, using plethysmography (PPG) signals alone, to estimate continuous blood pressure by extracting multiple PPG features related to intravascular blood flow characteristics. The performance of our method was evaluated using ten minutes synchronized PPG signals and continuous blood pressure from 21 healthy volunteers and 19 patients with hypertension and diabetes. The test results have shown that the absolute mean errors and standard deviation errors between the estimated and referenced blood pressure are 3.22±0.66 mmHg for systolic blood pressure and 2.11±1.11 mmHg for diastolic blood pressure, which meet AAMI (the association for the advancement of medical instrumentation) error acceptance.\",\"PeriodicalId\":386877,\"journal\":{\"name\":\"Computer Methods in Medicine and Health Care\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Medicine and Health Care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/atde210246\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Medicine and Health Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/atde210246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

持续监测血压对心血管疾病的预防和早期诊断具有重要意义。然而,现有的连续血压监测方法,特别是无袖血压监测方法,复杂且计算量大。在本文中,我们提出了一种方法,仅使用体积描记(PPG)信号,通过提取与血管内血流特征相关的多个PPG特征来估计连续血压。我们用21名健康志愿者和19名高血压合并糖尿病患者的10分钟同步PPG信号和连续血压来评估我们方法的性能。试验结果表明,估计血压与参考血压的绝对平均误差和标准差分别为收缩压3.22±0.66 mmHg和舒张压2.11±1.11 mmHg,符合美国医疗器械进步协会(AAMI)误差接受标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Continuous Blood Pressure Monitoring Method Based on Multiple Photoplethysmography Features
Continuous blood pressure monitoring is of great significance for the prevention and early diagnosis of cardiovascular diseases. However, the existing continuous blood pressure monitoring methods, especially the sleeveless blood pressure monitoring methods, are complex and computationally heavy. In this paper, we propose a method, using plethysmography (PPG) signals alone, to estimate continuous blood pressure by extracting multiple PPG features related to intravascular blood flow characteristics. The performance of our method was evaluated using ten minutes synchronized PPG signals and continuous blood pressure from 21 healthy volunteers and 19 patients with hypertension and diabetes. The test results have shown that the absolute mean errors and standard deviation errors between the estimated and referenced blood pressure are 3.22±0.66 mmHg for systolic blood pressure and 2.11±1.11 mmHg for diastolic blood pressure, which meet AAMI (the association for the advancement of medical instrumentation) error acceptance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信