{"title":"统一功率因数和降低谐波的三相升压整流器的优化控制","authors":"S. Fukuda, K. Koizumi","doi":"10.1109/PEDS.1995.404951","DOIUrl":null,"url":null,"abstract":"A vector controlled motor drive system consisting of a boost rectifier, inverter and induction motor is considered with emphasis placed on the rectifier side. Boost rectifiers can supply DC power while maintaining a sinusoidal AC current with an arbitrary value of fundamental power factor. They are required to simultaneously control both the DC voltage and the reactive current. A DSP-based discrete-time integral-type optimal regulator is considered for the control because it can provide a robust control system and can accommodate for the computational delay in the output. To obtain higher control performance, a DC load current feedforward signal from the inverter side is added.<<ETX>>","PeriodicalId":244042,"journal":{"name":"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95","volume":"14 12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Optimal control of a three phase boost rectifier for unity power factor and reduced harmonics\",\"authors\":\"S. Fukuda, K. Koizumi\",\"doi\":\"10.1109/PEDS.1995.404951\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A vector controlled motor drive system consisting of a boost rectifier, inverter and induction motor is considered with emphasis placed on the rectifier side. Boost rectifiers can supply DC power while maintaining a sinusoidal AC current with an arbitrary value of fundamental power factor. They are required to simultaneously control both the DC voltage and the reactive current. A DSP-based discrete-time integral-type optimal regulator is considered for the control because it can provide a robust control system and can accommodate for the computational delay in the output. To obtain higher control performance, a DC load current feedforward signal from the inverter side is added.<<ETX>>\",\"PeriodicalId\":244042,\"journal\":{\"name\":\"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95\",\"volume\":\"14 12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.1995.404951\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.1995.404951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimal control of a three phase boost rectifier for unity power factor and reduced harmonics
A vector controlled motor drive system consisting of a boost rectifier, inverter and induction motor is considered with emphasis placed on the rectifier side. Boost rectifiers can supply DC power while maintaining a sinusoidal AC current with an arbitrary value of fundamental power factor. They are required to simultaneously control both the DC voltage and the reactive current. A DSP-based discrete-time integral-type optimal regulator is considered for the control because it can provide a robust control system and can accommodate for the computational delay in the output. To obtain higher control performance, a DC load current feedforward signal from the inverter side is added.<>