{"title":"利用振荡梯度场的化学位移磁共振成像-一种短时傅里叶变换的方法","authors":"K. Takaya","doi":"10.1109/TFTSA.1992.274114","DOIUrl":null,"url":null,"abstract":"The author describes an approach to the problem of chemical-shift imaging using the short-time Fourier transform and the wavelet. When point sources of different chemical-shift values are measured with varying gradient field, these points travel along different loci in the instantaneous frequency vs. time diagram. Following the locus of a chemical-shift component of interest, the spatial distribution of the component can be observed with a varying degree of confidence. Taking an average over the profiles obtained at different gradient field intensities, the spatial profile solely due to a chemical-shift component can be reconstructed if each profile is scaled to the same bandwidth.<<ETX>>","PeriodicalId":105228,"journal":{"name":"[1992] Proceedings of the IEEE-SP International Symposium on Time-Frequency and Time-Scale Analysis","volume":"379 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Chemical shift MR imaging using oscillating gradient fields-an approach by the short-time Fourier transform\",\"authors\":\"K. Takaya\",\"doi\":\"10.1109/TFTSA.1992.274114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The author describes an approach to the problem of chemical-shift imaging using the short-time Fourier transform and the wavelet. When point sources of different chemical-shift values are measured with varying gradient field, these points travel along different loci in the instantaneous frequency vs. time diagram. Following the locus of a chemical-shift component of interest, the spatial distribution of the component can be observed with a varying degree of confidence. Taking an average over the profiles obtained at different gradient field intensities, the spatial profile solely due to a chemical-shift component can be reconstructed if each profile is scaled to the same bandwidth.<<ETX>>\",\"PeriodicalId\":105228,\"journal\":{\"name\":\"[1992] Proceedings of the IEEE-SP International Symposium on Time-Frequency and Time-Scale Analysis\",\"volume\":\"379 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1992] Proceedings of the IEEE-SP International Symposium on Time-Frequency and Time-Scale Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TFTSA.1992.274114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1992] Proceedings of the IEEE-SP International Symposium on Time-Frequency and Time-Scale Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TFTSA.1992.274114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Chemical shift MR imaging using oscillating gradient fields-an approach by the short-time Fourier transform
The author describes an approach to the problem of chemical-shift imaging using the short-time Fourier transform and the wavelet. When point sources of different chemical-shift values are measured with varying gradient field, these points travel along different loci in the instantaneous frequency vs. time diagram. Following the locus of a chemical-shift component of interest, the spatial distribution of the component can be observed with a varying degree of confidence. Taking an average over the profiles obtained at different gradient field intensities, the spatial profile solely due to a chemical-shift component can be reconstructed if each profile is scaled to the same bandwidth.<>