S. Patra, Sanjay Agrawal, S. Mohanty, V. Agarwal, M. Basu
{"title":"基于ESPRIT的并网逆变器鲁棒抗孤岛算法","authors":"S. Patra, Sanjay Agrawal, S. Mohanty, V. Agarwal, M. Basu","doi":"10.1109/TECHSYM.2016.7872661","DOIUrl":null,"url":null,"abstract":"This paper presents an anti-islanding protection scheme for a grid tied inverter. In this scheme, the oscillation variation in frequency is estimated by Estimation of Signal Parameters via Rotational Invariant Technique (ESPRIT). The proposed system is implemented in MATLAB and real time in OPAL-RT. Series of simulation results demonstrate that non-detection zone of proposed algorithm is negligible, and the scheme is also free from nuisance tripping to other transient events.","PeriodicalId":403350,"journal":{"name":"2016 IEEE Students’ Technology Symposium (TechSym)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"ESPRIT based robust anti-islanding algorithm for grid-tied inverter\",\"authors\":\"S. Patra, Sanjay Agrawal, S. Mohanty, V. Agarwal, M. Basu\",\"doi\":\"10.1109/TECHSYM.2016.7872661\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an anti-islanding protection scheme for a grid tied inverter. In this scheme, the oscillation variation in frequency is estimated by Estimation of Signal Parameters via Rotational Invariant Technique (ESPRIT). The proposed system is implemented in MATLAB and real time in OPAL-RT. Series of simulation results demonstrate that non-detection zone of proposed algorithm is negligible, and the scheme is also free from nuisance tripping to other transient events.\",\"PeriodicalId\":403350,\"journal\":{\"name\":\"2016 IEEE Students’ Technology Symposium (TechSym)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Students’ Technology Symposium (TechSym)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TECHSYM.2016.7872661\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Students’ Technology Symposium (TechSym)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TECHSYM.2016.7872661","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ESPRIT based robust anti-islanding algorithm for grid-tied inverter
This paper presents an anti-islanding protection scheme for a grid tied inverter. In this scheme, the oscillation variation in frequency is estimated by Estimation of Signal Parameters via Rotational Invariant Technique (ESPRIT). The proposed system is implemented in MATLAB and real time in OPAL-RT. Series of simulation results demonstrate that non-detection zone of proposed algorithm is negligible, and the scheme is also free from nuisance tripping to other transient events.