石英晶体精密温度试验台

R. Kinsman, D. Ryback
{"title":"石英晶体精密温度试验台","authors":"R. Kinsman, D. Ryback","doi":"10.1109/FREQ.1989.68882","DOIUrl":null,"url":null,"abstract":"A temperature test station has been developed for testing moderate quantities of crystal resonators. The primary function of this station is to accurately measure the frequency versus temperature characteristics of quartz crystals of all types. Additional features include curve-fitting routines to characterize the frequency-temperature function and the derivation of the crystal's equivalent circuit parameters as a function of temperature. In this system all electrical tests are performed by a network analyzer which interfaces directly with a computer. All functions of the network analyzer are controllable through the computer interface. Crystal measurements are performed with an HP 3577A network analyzer using the general methods outlined in EIA Crystal Measurement Standard 512. This work describes the equipment used in this station and provides a general description of the custom software used to operate the system. Estimates of system accuracy and repeatability are provided. Test results for a variety of crystals are given.<<ETX>>","PeriodicalId":294361,"journal":{"name":"Proceedings of the 43rd Annual Symposium on Frequency Control","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Precision temperature test station for quartz crystals\",\"authors\":\"R. Kinsman, D. Ryback\",\"doi\":\"10.1109/FREQ.1989.68882\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A temperature test station has been developed for testing moderate quantities of crystal resonators. The primary function of this station is to accurately measure the frequency versus temperature characteristics of quartz crystals of all types. Additional features include curve-fitting routines to characterize the frequency-temperature function and the derivation of the crystal's equivalent circuit parameters as a function of temperature. In this system all electrical tests are performed by a network analyzer which interfaces directly with a computer. All functions of the network analyzer are controllable through the computer interface. Crystal measurements are performed with an HP 3577A network analyzer using the general methods outlined in EIA Crystal Measurement Standard 512. This work describes the equipment used in this station and provides a general description of the custom software used to operate the system. Estimates of system accuracy and repeatability are provided. Test results for a variety of crystals are given.<<ETX>>\",\"PeriodicalId\":294361,\"journal\":{\"name\":\"Proceedings of the 43rd Annual Symposium on Frequency Control\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 43rd Annual Symposium on Frequency Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FREQ.1989.68882\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 43rd Annual Symposium on Frequency Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.1989.68882","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

研制了一个温度试验台,用于测试适量的晶体谐振器。该站的主要功能是精确测量各类石英晶体的频率与温度特性。附加功能包括曲线拟合程序,以表征频率-温度函数和晶体等效电路参数作为温度函数的推导。在这个系统中,所有的电气测试都是由一个直接与计算机连接的网络分析仪来完成的。通过计算机接口控制网络分析仪的所有功能。晶体测量使用HP 3577A网络分析仪执行,使用EIA晶体测量标准512中概述的一般方法。本工作描述了该站使用的设备,并提供了用于操作系统的定制软件的一般描述。给出了系统精度和可重复性的估计。给出了各种晶体的试验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Precision temperature test station for quartz crystals
A temperature test station has been developed for testing moderate quantities of crystal resonators. The primary function of this station is to accurately measure the frequency versus temperature characteristics of quartz crystals of all types. Additional features include curve-fitting routines to characterize the frequency-temperature function and the derivation of the crystal's equivalent circuit parameters as a function of temperature. In this system all electrical tests are performed by a network analyzer which interfaces directly with a computer. All functions of the network analyzer are controllable through the computer interface. Crystal measurements are performed with an HP 3577A network analyzer using the general methods outlined in EIA Crystal Measurement Standard 512. This work describes the equipment used in this station and provides a general description of the custom software used to operate the system. Estimates of system accuracy and repeatability are provided. Test results for a variety of crystals are given.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信