可调死区控制谐振缓冲器逆变器的死区补偿方案

N. Hoshi, Syoichi Nagata
{"title":"可调死区控制谐振缓冲器逆变器的死区补偿方案","authors":"N. Hoshi, Syoichi Nagata","doi":"10.1109/IPEMC.2009.5157626","DOIUrl":null,"url":null,"abstract":"Auxiliary resonant snubber inverters (RSIs) have been proposed a solution of demands for inverter, which are high efficiency and low EMI. In RSI, zero voltage switching (ZVS) on the inverter main switches is achieved by use of the auxiliary circuit; however, additional conduction loss increases simultaneously. The operating frequency of the auxiliary circuit in RSI can be reduced to a half of switching transition of a main switch when natural ZVS, in which ZVS can be achieved without using auxiliary circuit by using output current, is used. As a result, additional conduction loss can be suppressed. However, in this scheme, ZVS turn-on on main switch is failed near zero output current when dead-time was constant. As a solution for this problem, adjustable dead-time control scheme for RSI has been proposed; however, output current is distorted in low output power range. Thus, this paper proposes a dead-time compensation scheme for adjustable dead-time control. This paper shows the basic concept of the proposed compensation scheme. In addition, the effectiveness of the proposed scheme was verified through simulations using PSIM and experiments. As a result, it was verified that the proposed control scheme was able to improve THD without decreasing in efficiency.","PeriodicalId":375971,"journal":{"name":"2009 IEEE 6th International Power Electronics and Motion Control Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Dead-time compensation scheme for adjustable dead-time controlled resonant snubber inverter\",\"authors\":\"N. Hoshi, Syoichi Nagata\",\"doi\":\"10.1109/IPEMC.2009.5157626\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Auxiliary resonant snubber inverters (RSIs) have been proposed a solution of demands for inverter, which are high efficiency and low EMI. In RSI, zero voltage switching (ZVS) on the inverter main switches is achieved by use of the auxiliary circuit; however, additional conduction loss increases simultaneously. The operating frequency of the auxiliary circuit in RSI can be reduced to a half of switching transition of a main switch when natural ZVS, in which ZVS can be achieved without using auxiliary circuit by using output current, is used. As a result, additional conduction loss can be suppressed. However, in this scheme, ZVS turn-on on main switch is failed near zero output current when dead-time was constant. As a solution for this problem, adjustable dead-time control scheme for RSI has been proposed; however, output current is distorted in low output power range. Thus, this paper proposes a dead-time compensation scheme for adjustable dead-time control. This paper shows the basic concept of the proposed compensation scheme. In addition, the effectiveness of the proposed scheme was verified through simulations using PSIM and experiments. As a result, it was verified that the proposed control scheme was able to improve THD without decreasing in efficiency.\",\"PeriodicalId\":375971,\"journal\":{\"name\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2009.5157626\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 6th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2009.5157626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

辅助谐振缓冲器是一种高效率、低电磁干扰的逆变器。在RSI中,逆变器主开关上的零电压开关(ZVS)是利用辅助电路实现的;然而,额外的传导损失同时增加。当使用自然零电压时,RSI中辅助电路的工作频率可以降低到主开关开关过渡的一半,其中使用输出电流可以不使用辅助电路而实现零电压。因此,额外的传导损耗可以被抑制。然而,在此方案中,当死区时间一定时,总开关的ZVS导通在输出电流接近零时失败。针对这一问题,提出了可调死区控制方案;然而,在低输出功率范围内,输出电流失真。因此,本文提出了一种可调死区控制的死区补偿方案。本文阐述了所提出的补偿方案的基本概念。通过PSIM仿真和实验验证了该方案的有效性。结果验证了所提出的控制方案能够在不降低效率的情况下提高THD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dead-time compensation scheme for adjustable dead-time controlled resonant snubber inverter
Auxiliary resonant snubber inverters (RSIs) have been proposed a solution of demands for inverter, which are high efficiency and low EMI. In RSI, zero voltage switching (ZVS) on the inverter main switches is achieved by use of the auxiliary circuit; however, additional conduction loss increases simultaneously. The operating frequency of the auxiliary circuit in RSI can be reduced to a half of switching transition of a main switch when natural ZVS, in which ZVS can be achieved without using auxiliary circuit by using output current, is used. As a result, additional conduction loss can be suppressed. However, in this scheme, ZVS turn-on on main switch is failed near zero output current when dead-time was constant. As a solution for this problem, adjustable dead-time control scheme for RSI has been proposed; however, output current is distorted in low output power range. Thus, this paper proposes a dead-time compensation scheme for adjustable dead-time control. This paper shows the basic concept of the proposed compensation scheme. In addition, the effectiveness of the proposed scheme was verified through simulations using PSIM and experiments. As a result, it was verified that the proposed control scheme was able to improve THD without decreasing in efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信