{"title":"一种用于时域发射测量的新型矢量近场扫描系统","authors":"J. Russer, S. Braun","doi":"10.1109/ISEMC.2012.6351833","DOIUrl":null,"url":null,"abstract":"Traditionally, measurements of electromagnetic interference have been performed by EMI receivers operating in the frequency domain. Radiated emission measurements according to CISPR 16-2-3 are carried out below 1 GHz on open area test sites or in anechoic chambers with a conducting floor. Above 1 GHz, the measurements are carried out with a non-reflecting floor. The emission measurements are performed at several heights and angular positions to measure the maximum interference. Typical distances between the device under test and the antenna for measurements are 10 m for the frequency range 30 MHz-1 GHz. Time-domain measurements using the short-term fast Fourier transform have been introduced in the standards CISPR 16-1-1 and CISPR 16-2-3. They allow to reduce the test time significantly. Alternative methods, such as the measurement in a GTEM cell at three positions, have been introduced to reduce the test time. However, a drawback of the test methods for radiated emission measurements is the limited characterization of the device under test regarding near- and far-field in a spherical way. In this paper a novel vector near-field scanning system operating in time-domain is presented. Multichannel time domain EMI measurement systems open up new possibilities such as source reconstruction and far field evaluation. Using methods for stochastic electromagnetic field modeling, we present a near field scanning system that allows for source separation.","PeriodicalId":197346,"journal":{"name":"2012 IEEE International Symposium on Electromagnetic Compatibility","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A novel vector near-field scanning system for emission measurements in time-domain\",\"authors\":\"J. Russer, S. Braun\",\"doi\":\"10.1109/ISEMC.2012.6351833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Traditionally, measurements of electromagnetic interference have been performed by EMI receivers operating in the frequency domain. Radiated emission measurements according to CISPR 16-2-3 are carried out below 1 GHz on open area test sites or in anechoic chambers with a conducting floor. Above 1 GHz, the measurements are carried out with a non-reflecting floor. The emission measurements are performed at several heights and angular positions to measure the maximum interference. Typical distances between the device under test and the antenna for measurements are 10 m for the frequency range 30 MHz-1 GHz. Time-domain measurements using the short-term fast Fourier transform have been introduced in the standards CISPR 16-1-1 and CISPR 16-2-3. They allow to reduce the test time significantly. Alternative methods, such as the measurement in a GTEM cell at three positions, have been introduced to reduce the test time. However, a drawback of the test methods for radiated emission measurements is the limited characterization of the device under test regarding near- and far-field in a spherical way. In this paper a novel vector near-field scanning system operating in time-domain is presented. Multichannel time domain EMI measurement systems open up new possibilities such as source reconstruction and far field evaluation. Using methods for stochastic electromagnetic field modeling, we present a near field scanning system that allows for source separation.\",\"PeriodicalId\":197346,\"journal\":{\"name\":\"2012 IEEE International Symposium on Electromagnetic Compatibility\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2012.6351833\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2012.6351833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

传统上,电磁干扰的测量是由工作在频域的EMI接收器来完成的。根据CISPR 16-2-3进行的辐射发射测量在1 GHz以下的开放区域测试站点或在带有导电地板的消声室中进行。在1ghz以上,测量采用无反射底板。发射测量在几个高度和角度位置进行,以测量最大干涉。在30 MHz-1 GHz频率范围内,被测设备与用于测量的天线之间的典型距离为10米。使用短期快速傅立叶变换的时域测量已在标准CISPR 16-1-1和CISPR 16-2-3中引入。它们可以显著减少测试时间。替代方法,如在三个位置的GTEM细胞中测量,已被引入以减少测试时间。然而,用于辐射发射测量的测试方法的缺点是被测设备在近场和远场的球形方式的有限特性。本文提出了一种新颖的时域矢量近场扫描系统。多通道时域电磁干扰测量系统开辟了新的可能性,如源重建和远场评估。利用随机电磁场建模方法,我们提出了一种允许源分离的近场扫描系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel vector near-field scanning system for emission measurements in time-domain
Traditionally, measurements of electromagnetic interference have been performed by EMI receivers operating in the frequency domain. Radiated emission measurements according to CISPR 16-2-3 are carried out below 1 GHz on open area test sites or in anechoic chambers with a conducting floor. Above 1 GHz, the measurements are carried out with a non-reflecting floor. The emission measurements are performed at several heights and angular positions to measure the maximum interference. Typical distances between the device under test and the antenna for measurements are 10 m for the frequency range 30 MHz-1 GHz. Time-domain measurements using the short-term fast Fourier transform have been introduced in the standards CISPR 16-1-1 and CISPR 16-2-3. They allow to reduce the test time significantly. Alternative methods, such as the measurement in a GTEM cell at three positions, have been introduced to reduce the test time. However, a drawback of the test methods for radiated emission measurements is the limited characterization of the device under test regarding near- and far-field in a spherical way. In this paper a novel vector near-field scanning system operating in time-domain is presented. Multichannel time domain EMI measurement systems open up new possibilities such as source reconstruction and far field evaluation. Using methods for stochastic electromagnetic field modeling, we present a near field scanning system that allows for source separation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信