基于反射的腕表一体化脱水传感方法评价

F. Trenz, R. Weigel, D. Kissinger
{"title":"基于反射的腕表一体化脱水传感方法评价","authors":"F. Trenz, R. Weigel, D. Kissinger","doi":"10.1109/MIKON.2016.7491935","DOIUrl":null,"url":null,"abstract":"This paper presents a compact dehydration measurement method, keeping in mind a system integration in a wristwatch housing. In contrast to the conventional measurement approach using two measurement antennas, the proposed measurement setup uses only one antenna and one metallic reflector. Measurements have been performed using a patch antenna immersed in a steel basin filled with a tissue-equivalent liquid. The microstrip antenna has been optimized for an application in the 2.45GHz ISM band and features a biocompatible passivation layer and a rigid aluminum housing. The tissue-equivalent liquid mimicks dielectric tissue properties over a hypotonic hydration change. The steel basin acts as a liquid retainer and as a metallic reflector for the measurement setup. Measurements with the proposed setup have shown, that a clear distinction of physiologically relevant hydration levels is possible.","PeriodicalId":354299,"journal":{"name":"2016 21st International Conference on Microwave, Radar and Wireless Communications (MIKON)","volume":"31 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Evaluation of a reflection based dehydration sensing method for wristwatch integration\",\"authors\":\"F. Trenz, R. Weigel, D. Kissinger\",\"doi\":\"10.1109/MIKON.2016.7491935\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a compact dehydration measurement method, keeping in mind a system integration in a wristwatch housing. In contrast to the conventional measurement approach using two measurement antennas, the proposed measurement setup uses only one antenna and one metallic reflector. Measurements have been performed using a patch antenna immersed in a steel basin filled with a tissue-equivalent liquid. The microstrip antenna has been optimized for an application in the 2.45GHz ISM band and features a biocompatible passivation layer and a rigid aluminum housing. The tissue-equivalent liquid mimicks dielectric tissue properties over a hypotonic hydration change. The steel basin acts as a liquid retainer and as a metallic reflector for the measurement setup. Measurements with the proposed setup have shown, that a clear distinction of physiologically relevant hydration levels is possible.\",\"PeriodicalId\":354299,\"journal\":{\"name\":\"2016 21st International Conference on Microwave, Radar and Wireless Communications (MIKON)\",\"volume\":\"31 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 21st International Conference on Microwave, Radar and Wireless Communications (MIKON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MIKON.2016.7491935\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 21st International Conference on Microwave, Radar and Wireless Communications (MIKON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MIKON.2016.7491935","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提出了一种紧凑的脱水测量方法,考虑到手表外壳的系统集成。与使用两个测量天线的传统测量方法相比,所提出的测量装置仅使用一个天线和一个金属反射器。测量方法是将贴片天线浸入充满组织等效液体的钢盆中。该微带天线已针对2.45GHz ISM频段的应用进行了优化,并具有生物相容性钝化层和刚性铝外壳。组织等效液体在低渗水化变化中模拟介电组织特性。钢盆作为液体保持器和测量装置的金属反射器。用所提出的装置进行的测量表明,生理上相关的水合水平的明确区分是可能的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of a reflection based dehydration sensing method for wristwatch integration
This paper presents a compact dehydration measurement method, keeping in mind a system integration in a wristwatch housing. In contrast to the conventional measurement approach using two measurement antennas, the proposed measurement setup uses only one antenna and one metallic reflector. Measurements have been performed using a patch antenna immersed in a steel basin filled with a tissue-equivalent liquid. The microstrip antenna has been optimized for an application in the 2.45GHz ISM band and features a biocompatible passivation layer and a rigid aluminum housing. The tissue-equivalent liquid mimicks dielectric tissue properties over a hypotonic hydration change. The steel basin acts as a liquid retainer and as a metallic reflector for the measurement setup. Measurements with the proposed setup have shown, that a clear distinction of physiologically relevant hydration levels is possible.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信