H. Sakurai, S. Saito, T. Masuda, S. Gunji, M. Noma, G. Kanase, Y. Suzuki
{"title":"毛细管气体比例计数器中x射线光电子径迹的形式","authors":"H. Sakurai, S. Saito, T. Masuda, S. Gunji, M. Noma, G. Kanase, Y. Suzuki","doi":"10.1109/NSSMIC.1998.775134","DOIUrl":null,"url":null,"abstract":"We have successfully detected images of tracks of photoelectrons from the 22 keV and 30 keV X rays of /sup 109/Cd and /sup 241/Am, utilizing an optical imaging gas detector with a CCD camera. Most of the 30 keV photoelectrons have track lengths greater than 1 mm in xenon gas. The images of the tracks contain clusters of pixels, and the brightest of these clusters, for each track, were investigated in detail. It was found that the geometric center of these clusters differed from the point of maximum energy loss.","PeriodicalId":129202,"journal":{"name":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"The form of X-ray photoelectron tracks in a capillary gas proportional counter\",\"authors\":\"H. Sakurai, S. Saito, T. Masuda, S. Gunji, M. Noma, G. Kanase, Y. Suzuki\",\"doi\":\"10.1109/NSSMIC.1998.775134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have successfully detected images of tracks of photoelectrons from the 22 keV and 30 keV X rays of /sup 109/Cd and /sup 241/Am, utilizing an optical imaging gas detector with a CCD camera. Most of the 30 keV photoelectrons have track lengths greater than 1 mm in xenon gas. The images of the tracks contain clusters of pixels, and the brightest of these clusters, for each track, were investigated in detail. It was found that the geometric center of these clusters differed from the point of maximum energy loss.\",\"PeriodicalId\":129202,\"journal\":{\"name\":\"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1998.775134\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1998.775134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The form of X-ray photoelectron tracks in a capillary gas proportional counter
We have successfully detected images of tracks of photoelectrons from the 22 keV and 30 keV X rays of /sup 109/Cd and /sup 241/Am, utilizing an optical imaging gas detector with a CCD camera. Most of the 30 keV photoelectrons have track lengths greater than 1 mm in xenon gas. The images of the tracks contain clusters of pixels, and the brightest of these clusters, for each track, were investigated in detail. It was found that the geometric center of these clusters differed from the point of maximum energy loss.