C. Avigo, N. Di Lascio, C. Kusmic, F. Faita, L. Menichetti, P. Armanetti, G. Bocci, T. Di Desidero, N. Di Lascio, L. Menichetti
{"title":"体内组织表征的高频超声和光声成像","authors":"C. Avigo, N. Di Lascio, C. Kusmic, F. Faita, L. Menichetti, P. Armanetti, G. Bocci, T. Di Desidero, N. Di Lascio, L. Menichetti","doi":"10.1109/NANOFIM.2015.8425331","DOIUrl":null,"url":null,"abstract":"The photoacoustic (PA) technology combined with high frequency ultrasound (HF -US) is a versatile tool to assess real-time and non-invasively the morpho-functional and molecular information of a target tissue, and to map the distribution of contrast agents. Recently a plethora of novel nanomaterials were developed as contrast agents and/or drug delivery systems. In this work, we report the use of micro-bubbles and gold nanorods (GNRs) as vascular contrast agents for the characterization of tumor micro-environment, combining HF-US and PA imaging. A bolus of 50µL of untargeted micro-bubbles and a bolus of 150µL of GNRs solution were injected intravenously in two male colon cancer xenograft mice and detected with a commercial PA-US imaging system. The subcutaneous tumor dimensions were assessed by means of B-mode images (146.48 mm2and 24.56 mm2); different perfusion parameters were estimated tracking the micro-bubbles (peak enhancement map; time to peak 51,3s, 58,7s and 39s and wash-in rate 35,5s, 5,4s and 109,4s for different tumor regions); the real time distribution of GNRs in the tumor was assessed by means of the amplitude variation of the PA signal during time (30 % increase of the PA signal 28 min after injection). The combination of HF-US and PA imaging could become an efficient and non invasive tool for the in vivo and real-time evaluation of the tissue viability, to visualize the map of perfusion and monitoring the efficacy of drug/nano-particle delivery. The use of targeted microbubbles and nanoparticles could open new avenues for the real-time mapping of specific cell epitopes and phenotypes.","PeriodicalId":413629,"journal":{"name":"2015 1st Workshop on Nanotechnology in Instrumentation and Measurement (NANOFIM)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High frequency ultrasound and photoacoustic imaging for tissue characterization in vivo\",\"authors\":\"C. Avigo, N. Di Lascio, C. Kusmic, F. Faita, L. Menichetti, P. Armanetti, G. Bocci, T. Di Desidero, N. Di Lascio, L. Menichetti\",\"doi\":\"10.1109/NANOFIM.2015.8425331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The photoacoustic (PA) technology combined with high frequency ultrasound (HF -US) is a versatile tool to assess real-time and non-invasively the morpho-functional and molecular information of a target tissue, and to map the distribution of contrast agents. Recently a plethora of novel nanomaterials were developed as contrast agents and/or drug delivery systems. In this work, we report the use of micro-bubbles and gold nanorods (GNRs) as vascular contrast agents for the characterization of tumor micro-environment, combining HF-US and PA imaging. A bolus of 50µL of untargeted micro-bubbles and a bolus of 150µL of GNRs solution were injected intravenously in two male colon cancer xenograft mice and detected with a commercial PA-US imaging system. The subcutaneous tumor dimensions were assessed by means of B-mode images (146.48 mm2and 24.56 mm2); different perfusion parameters were estimated tracking the micro-bubbles (peak enhancement map; time to peak 51,3s, 58,7s and 39s and wash-in rate 35,5s, 5,4s and 109,4s for different tumor regions); the real time distribution of GNRs in the tumor was assessed by means of the amplitude variation of the PA signal during time (30 % increase of the PA signal 28 min after injection). The combination of HF-US and PA imaging could become an efficient and non invasive tool for the in vivo and real-time evaluation of the tissue viability, to visualize the map of perfusion and monitoring the efficacy of drug/nano-particle delivery. The use of targeted microbubbles and nanoparticles could open new avenues for the real-time mapping of specific cell epitopes and phenotypes.\",\"PeriodicalId\":413629,\"journal\":{\"name\":\"2015 1st Workshop on Nanotechnology in Instrumentation and Measurement (NANOFIM)\",\"volume\":\"91 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 1st Workshop on Nanotechnology in Instrumentation and Measurement (NANOFIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NANOFIM.2015.8425331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 1st Workshop on Nanotechnology in Instrumentation and Measurement (NANOFIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NANOFIM.2015.8425331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High frequency ultrasound and photoacoustic imaging for tissue characterization in vivo
The photoacoustic (PA) technology combined with high frequency ultrasound (HF -US) is a versatile tool to assess real-time and non-invasively the morpho-functional and molecular information of a target tissue, and to map the distribution of contrast agents. Recently a plethora of novel nanomaterials were developed as contrast agents and/or drug delivery systems. In this work, we report the use of micro-bubbles and gold nanorods (GNRs) as vascular contrast agents for the characterization of tumor micro-environment, combining HF-US and PA imaging. A bolus of 50µL of untargeted micro-bubbles and a bolus of 150µL of GNRs solution were injected intravenously in two male colon cancer xenograft mice and detected with a commercial PA-US imaging system. The subcutaneous tumor dimensions were assessed by means of B-mode images (146.48 mm2and 24.56 mm2); different perfusion parameters were estimated tracking the micro-bubbles (peak enhancement map; time to peak 51,3s, 58,7s and 39s and wash-in rate 35,5s, 5,4s and 109,4s for different tumor regions); the real time distribution of GNRs in the tumor was assessed by means of the amplitude variation of the PA signal during time (30 % increase of the PA signal 28 min after injection). The combination of HF-US and PA imaging could become an efficient and non invasive tool for the in vivo and real-time evaluation of the tissue viability, to visualize the map of perfusion and monitoring the efficacy of drug/nano-particle delivery. The use of targeted microbubbles and nanoparticles could open new avenues for the real-time mapping of specific cell epitopes and phenotypes.