整流罩环形声电流计的垂直余弦响应

A. Williams, A. Morrison, S. R. Brody
{"title":"整流罩环形声电流计的垂直余弦响应","authors":"A. Williams, A. Morrison, S. R. Brody","doi":"10.1109/CCM.2005.1506326","DOIUrl":null,"url":null,"abstract":"Measurement of current in the horizontal plane requires that the azimuth of the fluid velocity vector projected onto the horizontal plane be accurately represented in Cartesian coordinates with a cosine response in the x and y direction. In the acoustic current meter that was studied, MAVS (Modular Acoustic Velocity Sensor, manufactured by Nobska Development, Inc.), the horizontal cosine response is excellent, varying from ideal by less than 5%. When a full vector current measurement is made, there is a further requirement that the projection of the fluid velocity vector onto the vertical or z axis have a cosine response to the elevation angle of the velocity vector. Structures supporting the acoustic transducers in an acoustic current meter necessarily create wakes and distort the flow. Minimizing this disturbance through faired supports improves the vertical cosine response; however, there remains a velocity defect of as much as 20% for flows exceeding a 45/spl deg/ elevation angle in MAVS. For flows elevated less than 30/spl deg/ from the horizontal plane, the deviation from ideal cosine response is less than 10% and over a 50/spl deg/ range in elevation angle the deviation from ideal cosine response is less than 5%.","PeriodicalId":264883,"journal":{"name":"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2005-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Vertical cosine response of a faired ring acoustic current meter\",\"authors\":\"A. Williams, A. Morrison, S. R. Brody\",\"doi\":\"10.1109/CCM.2005.1506326\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of current in the horizontal plane requires that the azimuth of the fluid velocity vector projected onto the horizontal plane be accurately represented in Cartesian coordinates with a cosine response in the x and y direction. In the acoustic current meter that was studied, MAVS (Modular Acoustic Velocity Sensor, manufactured by Nobska Development, Inc.), the horizontal cosine response is excellent, varying from ideal by less than 5%. When a full vector current measurement is made, there is a further requirement that the projection of the fluid velocity vector onto the vertical or z axis have a cosine response to the elevation angle of the velocity vector. Structures supporting the acoustic transducers in an acoustic current meter necessarily create wakes and distort the flow. Minimizing this disturbance through faired supports improves the vertical cosine response; however, there remains a velocity defect of as much as 20% for flows exceeding a 45/spl deg/ elevation angle in MAVS. For flows elevated less than 30/spl deg/ from the horizontal plane, the deviation from ideal cosine response is less than 10% and over a 50/spl deg/ range in elevation angle the deviation from ideal cosine response is less than 5%.\",\"PeriodicalId\":264883,\"journal\":{\"name\":\"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCM.2005.1506326\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCM.2005.1506326","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

测量水平面上的电流要求投影到水平面上的流体速度矢量的方位角在笛卡尔坐标中精确地表示为x和y方向上的余弦响应。在研究的声学电流计MAVS(模块化声速传感器,由Nobska Development, Inc.制造)中,水平余弦响应非常好,与理想值相差不到5%。在进行全矢量电流测量时,还需要进一步要求流体速度矢量在垂直轴或z轴上的投影与速度矢量的仰角具有余弦响应。在声学电流计中,支撑声学换能器的结构必然会产生尾迹并扭曲水流。通过整流罩支架使这种干扰最小化,提高了垂直余弦响应;然而,在MAVS中,对于超过45/声压角/仰角的流动,仍然存在高达20%的速度缺陷。对于距离水平面高度小于30/spl°的流动,与理想余弦响应的偏差小于10%,在仰角高度超过50/spl°的范围内,与理想余弦响应的偏差小于5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Vertical cosine response of a faired ring acoustic current meter
Measurement of current in the horizontal plane requires that the azimuth of the fluid velocity vector projected onto the horizontal plane be accurately represented in Cartesian coordinates with a cosine response in the x and y direction. In the acoustic current meter that was studied, MAVS (Modular Acoustic Velocity Sensor, manufactured by Nobska Development, Inc.), the horizontal cosine response is excellent, varying from ideal by less than 5%. When a full vector current measurement is made, there is a further requirement that the projection of the fluid velocity vector onto the vertical or z axis have a cosine response to the elevation angle of the velocity vector. Structures supporting the acoustic transducers in an acoustic current meter necessarily create wakes and distort the flow. Minimizing this disturbance through faired supports improves the vertical cosine response; however, there remains a velocity defect of as much as 20% for flows exceeding a 45/spl deg/ elevation angle in MAVS. For flows elevated less than 30/spl deg/ from the horizontal plane, the deviation from ideal cosine response is less than 10% and over a 50/spl deg/ range in elevation angle the deviation from ideal cosine response is less than 5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信