存在谐波和畸变的广义负荷建模

S. Varadan, E. Makram
{"title":"存在谐波和畸变的广义负荷建模","authors":"S. Varadan, E. Makram","doi":"10.1109/SSST.1993.522755","DOIUrl":null,"url":null,"abstract":"The importance of using better load models in power system analyses is addressed. A new time-domain load modeling technique that is based on actual recorded steady state power system measurements is presented, and the incorporation of the load model developed into a harmonic load flow program that is based on the bus admittance matrix method is shown. The load model is perfectly general and can be used to model linear or nonlinear loads in the presence or absence of harmonic distortion. Since the model is based on physically realizable network elements, several harmonic-related problems can be addressed using the suggested approach. The problem of power factor correction in the presence of harmonics and distortion is used as an example to show the efficacy of the method.","PeriodicalId":260036,"journal":{"name":"1993 (25th) Southeastern Symposium on System Theory","volume":"143 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Generalized load modeling in the presence of harmonics and distortion\",\"authors\":\"S. Varadan, E. Makram\",\"doi\":\"10.1109/SSST.1993.522755\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The importance of using better load models in power system analyses is addressed. A new time-domain load modeling technique that is based on actual recorded steady state power system measurements is presented, and the incorporation of the load model developed into a harmonic load flow program that is based on the bus admittance matrix method is shown. The load model is perfectly general and can be used to model linear or nonlinear loads in the presence or absence of harmonic distortion. Since the model is based on physically realizable network elements, several harmonic-related problems can be addressed using the suggested approach. The problem of power factor correction in the presence of harmonics and distortion is used as an example to show the efficacy of the method.\",\"PeriodicalId\":260036,\"journal\":{\"name\":\"1993 (25th) Southeastern Symposium on System Theory\",\"volume\":\"143 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 (25th) Southeastern Symposium on System Theory\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SSST.1993.522755\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 (25th) Southeastern Symposium on System Theory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSST.1993.522755","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

讨论了在电力系统分析中使用更好的负荷模型的重要性。提出了一种基于实际稳态电力系统测量数据的时域负荷建模新技术,并将所建立的负荷模型整合到基于母线导纳矩阵法的谐波潮流程序中。负载模型是完全通用的,可用于在存在或不存在谐波畸变的情况下模拟线性或非线性负载。由于该模型基于物理上可实现的网络元素,因此可以使用建议的方法解决几个与谐波相关的问题。以存在谐波和失真的功率因数校正问题为例,说明了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Generalized load modeling in the presence of harmonics and distortion
The importance of using better load models in power system analyses is addressed. A new time-domain load modeling technique that is based on actual recorded steady state power system measurements is presented, and the incorporation of the load model developed into a harmonic load flow program that is based on the bus admittance matrix method is shown. The load model is perfectly general and can be used to model linear or nonlinear loads in the presence or absence of harmonic distortion. Since the model is based on physically realizable network elements, several harmonic-related problems can be addressed using the suggested approach. The problem of power factor correction in the presence of harmonics and distortion is used as an example to show the efficacy of the method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信