低压交流放电对聚合物表面劣化的原位质谱分析

R. S. Sigmond, T. Sigmond, A. Goldman, M. Goldman
{"title":"低压交流放电对聚合物表面劣化的原位质谱分析","authors":"R. S. Sigmond, T. Sigmond, A. Goldman, M. Goldman","doi":"10.1109/ICSD.1989.69239","DOIUrl":null,"url":null,"abstract":"Mass spectra of positive ions extracted from low-pressure (300-500 Pa) AC discharges to polymer surfaces show that polyethylene and polypropylene emit significant amounts of water when exposed to dry air of air-SF/sub 6/ coronas, and that this is due to the action of oxygen. This suggests that water trees in polymers may grow without externally supplied water if microdischarges and oxygen are present. The discharge conditions used, pd approximately=2.5 Pa-m, are near the Paschen minimum and correspond to a void of 25- mu m thickness at atmospheric pressure. This is the width at which a partial discharge will initiate at the lowest voltage. The corona ion source mass spectrometer has proved to be a very sensitive device for in situ measurement of the interaction between a gas discharge and a surface.<<ETX>>","PeriodicalId":184126,"journal":{"name":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"In situ mass spectrometric analysis of the deterioration of polymer surfaces by low pressure AC discharges\",\"authors\":\"R. S. Sigmond, T. Sigmond, A. Goldman, M. Goldman\",\"doi\":\"10.1109/ICSD.1989.69239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mass spectra of positive ions extracted from low-pressure (300-500 Pa) AC discharges to polymer surfaces show that polyethylene and polypropylene emit significant amounts of water when exposed to dry air of air-SF/sub 6/ coronas, and that this is due to the action of oxygen. This suggests that water trees in polymers may grow without externally supplied water if microdischarges and oxygen are present. The discharge conditions used, pd approximately=2.5 Pa-m, are near the Paschen minimum and correspond to a void of 25- mu m thickness at atmospheric pressure. This is the width at which a partial discharge will initiate at the lowest voltage. The corona ion source mass spectrometer has proved to be a very sensitive device for in situ measurement of the interaction between a gas discharge and a surface.<<ETX>>\",\"PeriodicalId\":184126,\"journal\":{\"name\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1989.69239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1989.69239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

从低压(300-500 Pa)交流放电到聚合物表面提取的正离子的质谱表明,聚乙烯和聚丙烯在暴露于空气- sf /sub - 6/ coronas的干燥空气时释放出大量的水,这是由于氧气的作用。这表明,如果存在微排放和氧气,聚合物中的水树可以在没有外部供水的情况下生长。所使用的放电条件pd约=2.5 Pa-m,接近Paschen最小值,对应于大气压下厚度为25 μ m的空洞。这是在最低电压下开始局部放电的宽度。电晕离子源质谱仪已被证明是一种非常灵敏的装置,可用于现场测量气体放电与表面之间的相互作用
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In situ mass spectrometric analysis of the deterioration of polymer surfaces by low pressure AC discharges
Mass spectra of positive ions extracted from low-pressure (300-500 Pa) AC discharges to polymer surfaces show that polyethylene and polypropylene emit significant amounts of water when exposed to dry air of air-SF/sub 6/ coronas, and that this is due to the action of oxygen. This suggests that water trees in polymers may grow without externally supplied water if microdischarges and oxygen are present. The discharge conditions used, pd approximately=2.5 Pa-m, are near the Paschen minimum and correspond to a void of 25- mu m thickness at atmospheric pressure. This is the width at which a partial discharge will initiate at the lowest voltage. The corona ion source mass spectrometer has proved to be a very sensitive device for in situ measurement of the interaction between a gas discharge and a surface.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信