{"title":"低压交流放电对聚合物表面劣化的原位质谱分析","authors":"R. S. Sigmond, T. Sigmond, A. Goldman, M. Goldman","doi":"10.1109/ICSD.1989.69239","DOIUrl":null,"url":null,"abstract":"Mass spectra of positive ions extracted from low-pressure (300-500 Pa) AC discharges to polymer surfaces show that polyethylene and polypropylene emit significant amounts of water when exposed to dry air of air-SF/sub 6/ coronas, and that this is due to the action of oxygen. This suggests that water trees in polymers may grow without externally supplied water if microdischarges and oxygen are present. The discharge conditions used, pd approximately=2.5 Pa-m, are near the Paschen minimum and correspond to a void of 25- mu m thickness at atmospheric pressure. This is the width at which a partial discharge will initiate at the lowest voltage. The corona ion source mass spectrometer has proved to be a very sensitive device for in situ measurement of the interaction between a gas discharge and a surface.<<ETX>>","PeriodicalId":184126,"journal":{"name":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"In situ mass spectrometric analysis of the deterioration of polymer surfaces by low pressure AC discharges\",\"authors\":\"R. S. Sigmond, T. Sigmond, A. Goldman, M. Goldman\",\"doi\":\"10.1109/ICSD.1989.69239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mass spectra of positive ions extracted from low-pressure (300-500 Pa) AC discharges to polymer surfaces show that polyethylene and polypropylene emit significant amounts of water when exposed to dry air of air-SF/sub 6/ coronas, and that this is due to the action of oxygen. This suggests that water trees in polymers may grow without externally supplied water if microdischarges and oxygen are present. The discharge conditions used, pd approximately=2.5 Pa-m, are near the Paschen minimum and correspond to a void of 25- mu m thickness at atmospheric pressure. This is the width at which a partial discharge will initiate at the lowest voltage. The corona ion source mass spectrometer has proved to be a very sensitive device for in situ measurement of the interaction between a gas discharge and a surface.<<ETX>>\",\"PeriodicalId\":184126,\"journal\":{\"name\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1989.69239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1989.69239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
从低压(300-500 Pa)交流放电到聚合物表面提取的正离子的质谱表明,聚乙烯和聚丙烯在暴露于空气- sf /sub - 6/ coronas的干燥空气时释放出大量的水,这是由于氧气的作用。这表明,如果存在微排放和氧气,聚合物中的水树可以在没有外部供水的情况下生长。所使用的放电条件pd约=2.5 Pa-m,接近Paschen最小值,对应于大气压下厚度为25 μ m的空洞。这是在最低电压下开始局部放电的宽度。电晕离子源质谱仪已被证明是一种非常灵敏的装置,可用于现场测量气体放电与表面之间的相互作用
In situ mass spectrometric analysis of the deterioration of polymer surfaces by low pressure AC discharges
Mass spectra of positive ions extracted from low-pressure (300-500 Pa) AC discharges to polymer surfaces show that polyethylene and polypropylene emit significant amounts of water when exposed to dry air of air-SF/sub 6/ coronas, and that this is due to the action of oxygen. This suggests that water trees in polymers may grow without externally supplied water if microdischarges and oxygen are present. The discharge conditions used, pd approximately=2.5 Pa-m, are near the Paschen minimum and correspond to a void of 25- mu m thickness at atmospheric pressure. This is the width at which a partial discharge will initiate at the lowest voltage. The corona ion source mass spectrometer has proved to be a very sensitive device for in situ measurement of the interaction between a gas discharge and a surface.<>