{"title":"一种用于低压直流微电网固态断路器母线故障保护的改进RCD缓冲器","authors":"Wenjun Liu, Hua Yang, Fei Liu, Jianjun Sun, X. Zha","doi":"10.1109/IFEEC.2015.7361508","DOIUrl":null,"url":null,"abstract":"An improved RCD snubber for solid-state circuit breaker (SSCB) is proposed in this paper in a low-voltage DC microgrid to protect SSCB against overvoltage caused by its tripping at the occurance of a DC-bus fault. Instead of relying mostly on the snubber capacitor to absorb the fault energy like commonly-used RCD snubbers, the proposed RCD snubber uses the snubber diode and an additional snubber resistor to form a separate path, which allows most of the energy to exhaust itself away from the snubber capacitor. In this way, the overvoltage across SSCB can be suppressed without increasing value and capacity of snubber capacitor, while the fault energy can also be quickly spent. Snubber process is discussed detailedly at a line-to-line fault to prove its effectiveness. Also, a design method is presented because former studies on parameter design of RCD snubber usually aim for converter appliance and cannot be directly applied on the proposed RCD snubber, which must be able to operate under fault current and thereby lays more stress in the peak value damping of overvoltage instead of quick suppression. Finally, simulations are conducted to prove its effectiveness in overvoltage suppression and fault current absorption.","PeriodicalId":268430,"journal":{"name":"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)","volume":"135 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"An improved RCD snubber for solid-state circuit breaker protection against bus fault in low-voltage DC microgrid\",\"authors\":\"Wenjun Liu, Hua Yang, Fei Liu, Jianjun Sun, X. Zha\",\"doi\":\"10.1109/IFEEC.2015.7361508\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An improved RCD snubber for solid-state circuit breaker (SSCB) is proposed in this paper in a low-voltage DC microgrid to protect SSCB against overvoltage caused by its tripping at the occurance of a DC-bus fault. Instead of relying mostly on the snubber capacitor to absorb the fault energy like commonly-used RCD snubbers, the proposed RCD snubber uses the snubber diode and an additional snubber resistor to form a separate path, which allows most of the energy to exhaust itself away from the snubber capacitor. In this way, the overvoltage across SSCB can be suppressed without increasing value and capacity of snubber capacitor, while the fault energy can also be quickly spent. Snubber process is discussed detailedly at a line-to-line fault to prove its effectiveness. Also, a design method is presented because former studies on parameter design of RCD snubber usually aim for converter appliance and cannot be directly applied on the proposed RCD snubber, which must be able to operate under fault current and thereby lays more stress in the peak value damping of overvoltage instead of quick suppression. Finally, simulations are conducted to prove its effectiveness in overvoltage suppression and fault current absorption.\",\"PeriodicalId\":268430,\"journal\":{\"name\":\"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)\",\"volume\":\"135 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IFEEC.2015.7361508\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFEEC.2015.7361508","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An improved RCD snubber for solid-state circuit breaker protection against bus fault in low-voltage DC microgrid
An improved RCD snubber for solid-state circuit breaker (SSCB) is proposed in this paper in a low-voltage DC microgrid to protect SSCB against overvoltage caused by its tripping at the occurance of a DC-bus fault. Instead of relying mostly on the snubber capacitor to absorb the fault energy like commonly-used RCD snubbers, the proposed RCD snubber uses the snubber diode and an additional snubber resistor to form a separate path, which allows most of the energy to exhaust itself away from the snubber capacitor. In this way, the overvoltage across SSCB can be suppressed without increasing value and capacity of snubber capacitor, while the fault energy can also be quickly spent. Snubber process is discussed detailedly at a line-to-line fault to prove its effectiveness. Also, a design method is presented because former studies on parameter design of RCD snubber usually aim for converter appliance and cannot be directly applied on the proposed RCD snubber, which must be able to operate under fault current and thereby lays more stress in the peak value damping of overvoltage instead of quick suppression. Finally, simulations are conducted to prove its effectiveness in overvoltage suppression and fault current absorption.