{"title":"端接非垂直立管传输线的电磁场耦合研究","authors":"Jun Guo, M. Rubinstein, V. Cooray, F. Rachidi","doi":"10.23919/URSIGASS49373.2020.9232394","DOIUrl":null,"url":null,"abstract":"Recently, a simple and efficient method was proposed to take into account non-vertical risers at the end of transmission lines through an equivalent partial inductance. This paper evaluates the frequency above which the inductance needs to be taken into account. In addition, the proposed method is validated in the time domain.","PeriodicalId":438881,"journal":{"name":"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science","volume":"129 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of Electromagnetic Field Coupling to a Transmission Line Terminated with Non-Vertical Risers\",\"authors\":\"Jun Guo, M. Rubinstein, V. Cooray, F. Rachidi\",\"doi\":\"10.23919/URSIGASS49373.2020.9232394\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, a simple and efficient method was proposed to take into account non-vertical risers at the end of transmission lines through an equivalent partial inductance. This paper evaluates the frequency above which the inductance needs to be taken into account. In addition, the proposed method is validated in the time domain.\",\"PeriodicalId\":438881,\"journal\":{\"name\":\"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science\",\"volume\":\"129 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/URSIGASS49373.2020.9232394\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/URSIGASS49373.2020.9232394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of Electromagnetic Field Coupling to a Transmission Line Terminated with Non-Vertical Risers
Recently, a simple and efficient method was proposed to take into account non-vertical risers at the end of transmission lines through an equivalent partial inductance. This paper evaluates the frequency above which the inductance needs to be taken into account. In addition, the proposed method is validated in the time domain.