Afonso Raposo, Rafael Silva, Luís Brás Rosário, João Sanches, H. P. da Silva
{"title":"使用双色摄像头的智能手机脉搏血氧仪","authors":"Afonso Raposo, Rafael Silva, Luís Brás Rosário, João Sanches, H. P. da Silva","doi":"10.1109/ENBENG58165.2023.10175332","DOIUrl":null,"url":null,"abstract":"SpO2monitoring is a non-invasive measure of blood oxygen saturation levels, particularly important to monitor respiratory and heart circulatory diseases. Incorporating SpO2 measurement into smartphones has the potential to improve patient access and cost-effective monitoring of health status. This paper presents a new smartphone camera-based photoplethys-mography technique for peripheral oxygen saturation measurement without external devices. Most existing methods have limitations for medical use due to a lack of accuracy and insufficient validation. Unlike other approaches, the proposed method uses the smartphone frontal camera and two-tone image patterns to control the emitted light spectrum, allowing for calibration and future clinical application. The method was tested on healthy subjects and demonstrated a strong correlation with reference values (r = −0.742). This approach improves camera-based oximetry acquisition and a validation protocol is also proposed for calibration, highlighting its clinical potential.","PeriodicalId":125330,"journal":{"name":"2023 IEEE 7th Portuguese Meeting on Bioengineering (ENBENG)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Smartphone Pulse Oximetry Using Two-tone Camera-based Photoplethysmography\",\"authors\":\"Afonso Raposo, Rafael Silva, Luís Brás Rosário, João Sanches, H. P. da Silva\",\"doi\":\"10.1109/ENBENG58165.2023.10175332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"SpO2monitoring is a non-invasive measure of blood oxygen saturation levels, particularly important to monitor respiratory and heart circulatory diseases. Incorporating SpO2 measurement into smartphones has the potential to improve patient access and cost-effective monitoring of health status. This paper presents a new smartphone camera-based photoplethys-mography technique for peripheral oxygen saturation measurement without external devices. Most existing methods have limitations for medical use due to a lack of accuracy and insufficient validation. Unlike other approaches, the proposed method uses the smartphone frontal camera and two-tone image patterns to control the emitted light spectrum, allowing for calibration and future clinical application. The method was tested on healthy subjects and demonstrated a strong correlation with reference values (r = −0.742). This approach improves camera-based oximetry acquisition and a validation protocol is also proposed for calibration, highlighting its clinical potential.\",\"PeriodicalId\":125330,\"journal\":{\"name\":\"2023 IEEE 7th Portuguese Meeting on Bioengineering (ENBENG)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE 7th Portuguese Meeting on Bioengineering (ENBENG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ENBENG58165.2023.10175332\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE 7th Portuguese Meeting on Bioengineering (ENBENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENBENG58165.2023.10175332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Smartphone Pulse Oximetry Using Two-tone Camera-based Photoplethysmography
SpO2monitoring is a non-invasive measure of blood oxygen saturation levels, particularly important to monitor respiratory and heart circulatory diseases. Incorporating SpO2 measurement into smartphones has the potential to improve patient access and cost-effective monitoring of health status. This paper presents a new smartphone camera-based photoplethys-mography technique for peripheral oxygen saturation measurement without external devices. Most existing methods have limitations for medical use due to a lack of accuracy and insufficient validation. Unlike other approaches, the proposed method uses the smartphone frontal camera and two-tone image patterns to control the emitted light spectrum, allowing for calibration and future clinical application. The method was tested on healthy subjects and demonstrated a strong correlation with reference values (r = −0.742). This approach improves camera-based oximetry acquisition and a validation protocol is also proposed for calibration, highlighting its clinical potential.