{"title":"基于matlab仿真的电力在线安全辅助决策系统研究","authors":"Wenfa Wang, Chunxue Xu, Shiyao Wang","doi":"10.2174/1874444301507011834","DOIUrl":null,"url":null,"abstract":"The parsing problems are due to the difference among COMTRADE standards, unreadable code in remote transmission and incompleteness of data in the power system. This paper presents an algorithm that can correctly parse the file in the Matlab format to the greatest extent. The algorithm includes the error pre-analysis part and the fault-tolerance parsing part. With the method of line-skipping parsing and validation, the error pre-analysis part can find all sorts of error that can influence the proper parsing and ultimately form an error information table. By inquiring the error information table and Matlab extension character table to parse the data file and obtain the validation information in advance, the fault tolerance parsing part reliably realizes fault-tolerance parsing of file in the Matlab format. Plentiful testing results of field data show that the new algorithm is practical and reliable, which can provide technical references to the development of any third-party transient data analysis software in a power system.","PeriodicalId":153592,"journal":{"name":"The Open Automation and Control Systems Journal","volume":"393 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research of Power Online Security Auxiliary Decision System Based onMatlab Simulation\",\"authors\":\"Wenfa Wang, Chunxue Xu, Shiyao Wang\",\"doi\":\"10.2174/1874444301507011834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The parsing problems are due to the difference among COMTRADE standards, unreadable code in remote transmission and incompleteness of data in the power system. This paper presents an algorithm that can correctly parse the file in the Matlab format to the greatest extent. The algorithm includes the error pre-analysis part and the fault-tolerance parsing part. With the method of line-skipping parsing and validation, the error pre-analysis part can find all sorts of error that can influence the proper parsing and ultimately form an error information table. By inquiring the error information table and Matlab extension character table to parse the data file and obtain the validation information in advance, the fault tolerance parsing part reliably realizes fault-tolerance parsing of file in the Matlab format. Plentiful testing results of field data show that the new algorithm is practical and reliable, which can provide technical references to the development of any third-party transient data analysis software in a power system.\",\"PeriodicalId\":153592,\"journal\":{\"name\":\"The Open Automation and Control Systems Journal\",\"volume\":\"393 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Open Automation and Control Systems Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1874444301507011834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Open Automation and Control Systems Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874444301507011834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research of Power Online Security Auxiliary Decision System Based onMatlab Simulation
The parsing problems are due to the difference among COMTRADE standards, unreadable code in remote transmission and incompleteness of data in the power system. This paper presents an algorithm that can correctly parse the file in the Matlab format to the greatest extent. The algorithm includes the error pre-analysis part and the fault-tolerance parsing part. With the method of line-skipping parsing and validation, the error pre-analysis part can find all sorts of error that can influence the proper parsing and ultimately form an error information table. By inquiring the error information table and Matlab extension character table to parse the data file and obtain the validation information in advance, the fault tolerance parsing part reliably realizes fault-tolerance parsing of file in the Matlab format. Plentiful testing results of field data show that the new algorithm is practical and reliable, which can provide technical references to the development of any third-party transient data analysis software in a power system.