LED灯的寿命和光学分析

E. R. Santos, Hélio Akira Furuya, E. C. Burini Júnior
{"title":"LED灯的寿命和光学分析","authors":"E. R. Santos, Hélio Akira Furuya, E. C. Burini Júnior","doi":"10.17563/rbav.v40i1.1208","DOIUrl":null,"url":null,"abstract":"In this study, optical and lifetime analyses of commercial light-emitting diode (LED) lamps were carried out with the objective to better understand these characteristics. Lamps of different manufacturers and powers were used: Ourolux of 9 watts, Kian of 9 watts, Black+Decker of 9 watts, FLC of 8 watts, Galaxy of 7 watts and Brilia of 7 watts. These LED lamps remained on by 24 hours/day for 4,291.16 hours. Illuminance measurements were analyzed once a week by each lamp inside the integrating sphere with a sensor of lux meter coupled. Results showed decrease of illuminance by elapsed time, due to the degradation. Results of the illuminance obtained between the initial moment of the experiment and the final one were calculated, revealing degradation of 19% to Ourolux, 20% to FLC, 26% to Black+Decker, 28% to Kian, 29% to Galaxy and 33% to Brilia. This study suggests that the diffusers can have different transmittance values interfering on the illuminance, since the FLC LED lamp presented illuminance with highest values than the other LED lamps tested with similar electrical and optical characteristics. This experiment showed that the nominal power of the LED lamp has no direct relation to the illuminance and, comparing the lifetime, the LED lamp manufactured by Black+Decker was the only one to reach 5,521 hours, that is a lifetime much shorter than the one described at the packages (25,000 hours) for all LED lamps tested","PeriodicalId":237166,"journal":{"name":"Revista Brasileira de Aplicações de Vácuo","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lifetime and optical analyses of LED lamps\",\"authors\":\"E. R. Santos, Hélio Akira Furuya, E. C. Burini Júnior\",\"doi\":\"10.17563/rbav.v40i1.1208\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, optical and lifetime analyses of commercial light-emitting diode (LED) lamps were carried out with the objective to better understand these characteristics. Lamps of different manufacturers and powers were used: Ourolux of 9 watts, Kian of 9 watts, Black+Decker of 9 watts, FLC of 8 watts, Galaxy of 7 watts and Brilia of 7 watts. These LED lamps remained on by 24 hours/day for 4,291.16 hours. Illuminance measurements were analyzed once a week by each lamp inside the integrating sphere with a sensor of lux meter coupled. Results showed decrease of illuminance by elapsed time, due to the degradation. Results of the illuminance obtained between the initial moment of the experiment and the final one were calculated, revealing degradation of 19% to Ourolux, 20% to FLC, 26% to Black+Decker, 28% to Kian, 29% to Galaxy and 33% to Brilia. This study suggests that the diffusers can have different transmittance values interfering on the illuminance, since the FLC LED lamp presented illuminance with highest values than the other LED lamps tested with similar electrical and optical characteristics. This experiment showed that the nominal power of the LED lamp has no direct relation to the illuminance and, comparing the lifetime, the LED lamp manufactured by Black+Decker was the only one to reach 5,521 hours, that is a lifetime much shorter than the one described at the packages (25,000 hours) for all LED lamps tested\",\"PeriodicalId\":237166,\"journal\":{\"name\":\"Revista Brasileira de Aplicações de Vácuo\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Aplicações de Vácuo\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17563/rbav.v40i1.1208\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Aplicações de Vácuo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17563/rbav.v40i1.1208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本研究中,为了更好地了解这些特性,对商用发光二极管(LED)灯进行了光学和寿命分析。使用了不同厂家和功率的灯:9瓦的Ourolux、9瓦的Kian、9瓦的Black+Decker、8瓦的FLC、7瓦的Galaxy和7瓦的Brilia。这些LED灯每天24小时保持亮着,共计4291.16小时。积分球内每盏灯与勒克斯计传感器耦合,每周分析一次照度测量。结果表明,由于降解,随着时间的流逝,照度降低。计算从实验开始时刻到最终时刻的照度结果,显示对Ourolux的降解率为19%,对FLC的降解率为20%,对Black+Decker的降解率为26%,对Kian的降解率为28%,对Galaxy的降解率为29%,对briilia的降解率为33%。本研究表明,扩散器具有不同的透过率值会对照度产生干扰,因为FLC LED灯的照度值高于其他具有相似电学和光学特性的LED灯。该实验表明,LED灯的标称功率与照度没有直接关系,并且比较寿命,Black+Decker制造的LED灯是唯一达到5,521小时的LED灯,这比所有LED灯在封装中描述的寿命(25,000小时)短得多
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lifetime and optical analyses of LED lamps
In this study, optical and lifetime analyses of commercial light-emitting diode (LED) lamps were carried out with the objective to better understand these characteristics. Lamps of different manufacturers and powers were used: Ourolux of 9 watts, Kian of 9 watts, Black+Decker of 9 watts, FLC of 8 watts, Galaxy of 7 watts and Brilia of 7 watts. These LED lamps remained on by 24 hours/day for 4,291.16 hours. Illuminance measurements were analyzed once a week by each lamp inside the integrating sphere with a sensor of lux meter coupled. Results showed decrease of illuminance by elapsed time, due to the degradation. Results of the illuminance obtained between the initial moment of the experiment and the final one were calculated, revealing degradation of 19% to Ourolux, 20% to FLC, 26% to Black+Decker, 28% to Kian, 29% to Galaxy and 33% to Brilia. This study suggests that the diffusers can have different transmittance values interfering on the illuminance, since the FLC LED lamp presented illuminance with highest values than the other LED lamps tested with similar electrical and optical characteristics. This experiment showed that the nominal power of the LED lamp has no direct relation to the illuminance and, comparing the lifetime, the LED lamp manufactured by Black+Decker was the only one to reach 5,521 hours, that is a lifetime much shorter than the one described at the packages (25,000 hours) for all LED lamps tested
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信