4 GHz和14 GHz SFCW雷达测量小实验动物生命体征的比较

L. Anishchenko, Ekatherina Gaysina
{"title":"4 GHz和14 GHz SFCW雷达测量小实验动物生命体征的比较","authors":"L. Anishchenko, Ekatherina Gaysina","doi":"10.1109/COMCAS.2015.7360388","DOIUrl":null,"url":null,"abstract":"The work presents a feasibility study on the possible bioradar devices usage for contactless monitoring of the laboratory animals respiratory rhythm. Experiments are performed in laboratory conditions on sleeping rats by using two SFCW radars operating at frequency ranges of 3.6-4.0 GHz and 13.8-14.2 GHz. Respiration pattern and movement activity of a rat were monitored by each radar. Experimental results analysis revealed that usage of higher probing frequencies is more preferable and allows reliable estimation of respiratory pattern of laboratory animals in sleep.","PeriodicalId":431569,"journal":{"name":"2015 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems (COMCAS)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Comparison of 4 GHz and 14 GHz SFCW radars in measuring of small laboratory animals vital signs\",\"authors\":\"L. Anishchenko, Ekatherina Gaysina\",\"doi\":\"10.1109/COMCAS.2015.7360388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The work presents a feasibility study on the possible bioradar devices usage for contactless monitoring of the laboratory animals respiratory rhythm. Experiments are performed in laboratory conditions on sleeping rats by using two SFCW radars operating at frequency ranges of 3.6-4.0 GHz and 13.8-14.2 GHz. Respiration pattern and movement activity of a rat were monitored by each radar. Experimental results analysis revealed that usage of higher probing frequencies is more preferable and allows reliable estimation of respiratory pattern of laboratory animals in sleep.\",\"PeriodicalId\":431569,\"journal\":{\"name\":\"2015 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems (COMCAS)\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems (COMCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COMCAS.2015.7360388\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems (COMCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMCAS.2015.7360388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

这项工作提出了一项关于生物雷达设备用于实验室动物呼吸节律非接触监测的可行性研究。实验在实验室条件下对睡眠大鼠进行,使用两台SFCW雷达,工作频率范围为3.6-4.0 GHz和13.8-14.2 GHz。每个雷达监测大鼠的呼吸模式和运动活动。实验结果分析表明,使用更高的探测频率更可取,并且可以可靠地估计实验动物在睡眠中的呼吸模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of 4 GHz and 14 GHz SFCW radars in measuring of small laboratory animals vital signs
The work presents a feasibility study on the possible bioradar devices usage for contactless monitoring of the laboratory animals respiratory rhythm. Experiments are performed in laboratory conditions on sleeping rats by using two SFCW radars operating at frequency ranges of 3.6-4.0 GHz and 13.8-14.2 GHz. Respiration pattern and movement activity of a rat were monitored by each radar. Experimental results analysis revealed that usage of higher probing frequencies is more preferable and allows reliable estimation of respiratory pattern of laboratory animals in sleep.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信