{"title":"用于硬x射线和低能伽玛射线天文学的高压Xe电离探测器的研制","authors":"A. Bolotnikov, B. Ramsey","doi":"10.1109/NSSMIC.1995.504221","DOIUrl":null,"url":null,"abstract":"A purification system, purity and density monitors, and the design of a high-pressure Xe cylindrical ionization chamber have been tested as apart of a development of high-pressure Xe detectors for X-ray and gamma-ray astronomy. Preliminary results from the high-pressure Xe cylindrical ionization chamber confirms advantages of such detectors for hard X-rays and low energy gamma-rays.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of high-pressure Xe ionization detectors for hard X-ray and low energy gamma-ray astronomy\",\"authors\":\"A. Bolotnikov, B. Ramsey\",\"doi\":\"10.1109/NSSMIC.1995.504221\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A purification system, purity and density monitors, and the design of a high-pressure Xe cylindrical ionization chamber have been tested as apart of a development of high-pressure Xe detectors for X-ray and gamma-ray astronomy. Preliminary results from the high-pressure Xe cylindrical ionization chamber confirms advantages of such detectors for hard X-rays and low energy gamma-rays.\",\"PeriodicalId\":409998,\"journal\":{\"name\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1995.504221\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.504221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of high-pressure Xe ionization detectors for hard X-ray and low energy gamma-ray astronomy
A purification system, purity and density monitors, and the design of a high-pressure Xe cylindrical ionization chamber have been tested as apart of a development of high-pressure Xe detectors for X-ray and gamma-ray astronomy. Preliminary results from the high-pressure Xe cylindrical ionization chamber confirms advantages of such detectors for hard X-rays and low energy gamma-rays.