{"title":"LCL型单相并网逆变器控制策略研究","authors":"Xin Liu, Panwei Ma, Genhua He, Dong Wang","doi":"10.1109/ICMCCE.2018.00016","DOIUrl":null,"url":null,"abstract":"For the problems of traditional LCL-type grid-connected inverters have resonance spikes and grid-connected inverters of split-capacitor single-loop control have low power factor. A novel dual-current loop control strategy is proposed in which the split-capacitor intermediate current is used as the inner loop and the grid-connected current is used as the outer loop. The simulation results of Matlab/Simulink are given. The simulation results show that the LCL type single-phase grid-connected inverter can achieve low-harmonic and high-power factor grid connection using this strategy, which verifies the feasibility of this control strategy.","PeriodicalId":198834,"journal":{"name":"2018 3rd International Conference on Mechanical, Control and Computer Engineering (ICMCCE)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Study on Control Strategy of LCL Type Single-Phase Grid-Connected Inverter\",\"authors\":\"Xin Liu, Panwei Ma, Genhua He, Dong Wang\",\"doi\":\"10.1109/ICMCCE.2018.00016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For the problems of traditional LCL-type grid-connected inverters have resonance spikes and grid-connected inverters of split-capacitor single-loop control have low power factor. A novel dual-current loop control strategy is proposed in which the split-capacitor intermediate current is used as the inner loop and the grid-connected current is used as the outer loop. The simulation results of Matlab/Simulink are given. The simulation results show that the LCL type single-phase grid-connected inverter can achieve low-harmonic and high-power factor grid connection using this strategy, which verifies the feasibility of this control strategy.\",\"PeriodicalId\":198834,\"journal\":{\"name\":\"2018 3rd International Conference on Mechanical, Control and Computer Engineering (ICMCCE)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 3rd International Conference on Mechanical, Control and Computer Engineering (ICMCCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMCCE.2018.00016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 3rd International Conference on Mechanical, Control and Computer Engineering (ICMCCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMCCE.2018.00016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study on Control Strategy of LCL Type Single-Phase Grid-Connected Inverter
For the problems of traditional LCL-type grid-connected inverters have resonance spikes and grid-connected inverters of split-capacitor single-loop control have low power factor. A novel dual-current loop control strategy is proposed in which the split-capacitor intermediate current is used as the inner loop and the grid-connected current is used as the outer loop. The simulation results of Matlab/Simulink are given. The simulation results show that the LCL type single-phase grid-connected inverter can achieve low-harmonic and high-power factor grid connection using this strategy, which verifies the feasibility of this control strategy.