{"title":"张力测量试验系统的设计、标定及测量不确定度分析","authors":"H. Cetin, Gokhan Ozturk, Y. Celebi, A. Dindar","doi":"10.1109/I2MTC.2015.7151570","DOIUrl":null,"url":null,"abstract":"In this article; design, calibration and measurement uncertainty analysis of a tension measurement test system are presented. This system is designed for measuring tension force on a towed array which is towed behind surface ships via a cable. A special test setup that simulates the static and dynamic conditions for the measurement system is prepared for the calibration process. Calibration of the measurement system is carried out using different loads which are changed from 150 kg to 2500 kg by 150 kg increments. Then regression analysis is conducted by applying curve fitting procedure and lack of fit test for static and dynamic conditions separately. Data acquired by the measurement system in the calibration tests are analyzed by calculating measurement uncertainties in the test system. Standard uncertainties due to calibration data errors, instrument errors and curve fitting process are determined for static and dynamic conditions. In addition, combined and expanded uncertainties are calculated and compared to each other.","PeriodicalId":424006,"journal":{"name":"2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design, calibration and measurement uncertainty analysis of a tension measurement test system\",\"authors\":\"H. Cetin, Gokhan Ozturk, Y. Celebi, A. Dindar\",\"doi\":\"10.1109/I2MTC.2015.7151570\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article; design, calibration and measurement uncertainty analysis of a tension measurement test system are presented. This system is designed for measuring tension force on a towed array which is towed behind surface ships via a cable. A special test setup that simulates the static and dynamic conditions for the measurement system is prepared for the calibration process. Calibration of the measurement system is carried out using different loads which are changed from 150 kg to 2500 kg by 150 kg increments. Then regression analysis is conducted by applying curve fitting procedure and lack of fit test for static and dynamic conditions separately. Data acquired by the measurement system in the calibration tests are analyzed by calculating measurement uncertainties in the test system. Standard uncertainties due to calibration data errors, instrument errors and curve fitting process are determined for static and dynamic conditions. In addition, combined and expanded uncertainties are calculated and compared to each other.\",\"PeriodicalId\":424006,\"journal\":{\"name\":\"2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC.2015.7151570\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2015.7151570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design, calibration and measurement uncertainty analysis of a tension measurement test system
In this article; design, calibration and measurement uncertainty analysis of a tension measurement test system are presented. This system is designed for measuring tension force on a towed array which is towed behind surface ships via a cable. A special test setup that simulates the static and dynamic conditions for the measurement system is prepared for the calibration process. Calibration of the measurement system is carried out using different loads which are changed from 150 kg to 2500 kg by 150 kg increments. Then regression analysis is conducted by applying curve fitting procedure and lack of fit test for static and dynamic conditions separately. Data acquired by the measurement system in the calibration tests are analyzed by calculating measurement uncertainties in the test system. Standard uncertainties due to calibration data errors, instrument errors and curve fitting process are determined for static and dynamic conditions. In addition, combined and expanded uncertainties are calculated and compared to each other.