Bingxin X. Yang, A. Lumpkin, G. Goeppner, S. Sharma, E. Rotela, I. Sheng, E. Moog
{"title":"APS诊断波束线的状态","authors":"Bingxin X. Yang, A. Lumpkin, G. Goeppner, S. Sharma, E. Rotela, I. Sheng, E. Moog","doi":"10.1109/PAC.1997.751157","DOIUrl":null,"url":null,"abstract":"We report the status of the diagnostics undulator beamline for the Advanced Photon Source (APS) storage ring. The beamline was designed for the characterization of the 7-GeV, low-emittance positron beam at high resolution. The special diagnostics undulator has been manufactured by STI Optronics. The device exhibits very low magnetic field errors at closed gap of 10.5 mm: first field integral less than 15 gauss/spl middot/cm, and optical phase error less than 1.5/spl deg/. The front end of the beamline and a monochromator are installed and tested for use on divergence and directional stability measurements with a target resolution of 3 /spl mu/rad utilizing the first harmonic radiation of 25 keV. Initial results for the divergence measurement show that the storage ring is operating well within its design goals.","PeriodicalId":122662,"journal":{"name":"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Status of the APS diagnostics undulator beamline\",\"authors\":\"Bingxin X. Yang, A. Lumpkin, G. Goeppner, S. Sharma, E. Rotela, I. Sheng, E. Moog\",\"doi\":\"10.1109/PAC.1997.751157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report the status of the diagnostics undulator beamline for the Advanced Photon Source (APS) storage ring. The beamline was designed for the characterization of the 7-GeV, low-emittance positron beam at high resolution. The special diagnostics undulator has been manufactured by STI Optronics. The device exhibits very low magnetic field errors at closed gap of 10.5 mm: first field integral less than 15 gauss/spl middot/cm, and optical phase error less than 1.5/spl deg/. The front end of the beamline and a monochromator are installed and tested for use on divergence and directional stability measurements with a target resolution of 3 /spl mu/rad utilizing the first harmonic radiation of 25 keV. Initial results for the divergence measurement show that the storage ring is operating well within its design goals.\",\"PeriodicalId\":122662,\"journal\":{\"name\":\"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAC.1997.751157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1997.751157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
We report the status of the diagnostics undulator beamline for the Advanced Photon Source (APS) storage ring. The beamline was designed for the characterization of the 7-GeV, low-emittance positron beam at high resolution. The special diagnostics undulator has been manufactured by STI Optronics. The device exhibits very low magnetic field errors at closed gap of 10.5 mm: first field integral less than 15 gauss/spl middot/cm, and optical phase error less than 1.5/spl deg/. The front end of the beamline and a monochromator are installed and tested for use on divergence and directional stability measurements with a target resolution of 3 /spl mu/rad utilizing the first harmonic radiation of 25 keV. Initial results for the divergence measurement show that the storage ring is operating well within its design goals.