{"title":"时序电路中部分路径激活的动态时序分析","authors":"P. Agrawal, V. Agrawal, S. Seth","doi":"10.1109/EURDAC.1992.246252","DOIUrl":null,"url":null,"abstract":"The authors provide a method of finding all sensitizable paths in a non-scan synchronous sequential circuit. Path activation conditions of the circuit are mapped onto a single stuck type fault by adding a few modeling gates to the netlist. The path is considered to be sensitizable only if the corresponding stuck type fault is found detectable by a sequential circuit test generator. A depth-first analysis of circuit topology that determines all paths between primary inputs, primary outputs and flip-flops employs a partial path hierarchy. All paths with a common unsensitizable segment need not be examined separately. Results on benchmark circuits show that: (1) the number of sensitizable paths can be significantly smaller than that found by a static timing analyzer, and (2) the partial path analysis adds to efficiency when the number of sensitizable paths is less than 20%.<<ETX>>","PeriodicalId":218056,"journal":{"name":"Proceedings EURO-DAC '92: European Design Automation Conference","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"DynaTAPP: dynamic timing analysis with partial path activation in sequential circuits\",\"authors\":\"P. Agrawal, V. Agrawal, S. Seth\",\"doi\":\"10.1109/EURDAC.1992.246252\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors provide a method of finding all sensitizable paths in a non-scan synchronous sequential circuit. Path activation conditions of the circuit are mapped onto a single stuck type fault by adding a few modeling gates to the netlist. The path is considered to be sensitizable only if the corresponding stuck type fault is found detectable by a sequential circuit test generator. A depth-first analysis of circuit topology that determines all paths between primary inputs, primary outputs and flip-flops employs a partial path hierarchy. All paths with a common unsensitizable segment need not be examined separately. Results on benchmark circuits show that: (1) the number of sensitizable paths can be significantly smaller than that found by a static timing analyzer, and (2) the partial path analysis adds to efficiency when the number of sensitizable paths is less than 20%.<<ETX>>\",\"PeriodicalId\":218056,\"journal\":{\"name\":\"Proceedings EURO-DAC '92: European Design Automation Conference\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings EURO-DAC '92: European Design Automation Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EURDAC.1992.246252\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings EURO-DAC '92: European Design Automation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EURDAC.1992.246252","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
DynaTAPP: dynamic timing analysis with partial path activation in sequential circuits
The authors provide a method of finding all sensitizable paths in a non-scan synchronous sequential circuit. Path activation conditions of the circuit are mapped onto a single stuck type fault by adding a few modeling gates to the netlist. The path is considered to be sensitizable only if the corresponding stuck type fault is found detectable by a sequential circuit test generator. A depth-first analysis of circuit topology that determines all paths between primary inputs, primary outputs and flip-flops employs a partial path hierarchy. All paths with a common unsensitizable segment need not be examined separately. Results on benchmark circuits show that: (1) the number of sensitizable paths can be significantly smaller than that found by a static timing analyzer, and (2) the partial path analysis adds to efficiency when the number of sensitizable paths is less than 20%.<>