{"title":"变电站环境风机联动系统烟气远程监测方法","authors":"Jianzhong Shen, Shuai An, Chenjie Wang","doi":"10.1109/AINIT54228.2021.00096","DOIUrl":null,"url":null,"abstract":"Aiming at the problem of poor accuracy of traditional substation environmental smoke remote monitoring, a remote monitoring method of substation environmental fan linkage system is proposed. This article optimizes the smoke remote monitoring equipment, thereby improving the monitoring sensitivity. The smoke concentration level is further divided, and the smoke level warning setting of the fan linkage system is realized. On this basis, the remote smoke monitoring process of the substation environmental fan linkage system is optimized, thereby improving the efficiency of remote monitoring and early warning of substation smoke, and strengthening the effect of remote monitoring of substation environmental smoke. The experimental results show that the proposed remote monitoring method for the flue gas of the substation environmental fan linkage system has high monitoring accuracy in the actual application process.","PeriodicalId":326400,"journal":{"name":"2021 2nd International Seminar on Artificial Intelligence, Networking and Information Technology (AINIT)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Smoke Remote Monitoring Method for Environmental Fan Linkage System in Substation\",\"authors\":\"Jianzhong Shen, Shuai An, Chenjie Wang\",\"doi\":\"10.1109/AINIT54228.2021.00096\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aiming at the problem of poor accuracy of traditional substation environmental smoke remote monitoring, a remote monitoring method of substation environmental fan linkage system is proposed. This article optimizes the smoke remote monitoring equipment, thereby improving the monitoring sensitivity. The smoke concentration level is further divided, and the smoke level warning setting of the fan linkage system is realized. On this basis, the remote smoke monitoring process of the substation environmental fan linkage system is optimized, thereby improving the efficiency of remote monitoring and early warning of substation smoke, and strengthening the effect of remote monitoring of substation environmental smoke. The experimental results show that the proposed remote monitoring method for the flue gas of the substation environmental fan linkage system has high monitoring accuracy in the actual application process.\",\"PeriodicalId\":326400,\"journal\":{\"name\":\"2021 2nd International Seminar on Artificial Intelligence, Networking and Information Technology (AINIT)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 2nd International Seminar on Artificial Intelligence, Networking and Information Technology (AINIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AINIT54228.2021.00096\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 2nd International Seminar on Artificial Intelligence, Networking and Information Technology (AINIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AINIT54228.2021.00096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Smoke Remote Monitoring Method for Environmental Fan Linkage System in Substation
Aiming at the problem of poor accuracy of traditional substation environmental smoke remote monitoring, a remote monitoring method of substation environmental fan linkage system is proposed. This article optimizes the smoke remote monitoring equipment, thereby improving the monitoring sensitivity. The smoke concentration level is further divided, and the smoke level warning setting of the fan linkage system is realized. On this basis, the remote smoke monitoring process of the substation environmental fan linkage system is optimized, thereby improving the efficiency of remote monitoring and early warning of substation smoke, and strengthening the effect of remote monitoring of substation environmental smoke. The experimental results show that the proposed remote monitoring method for the flue gas of the substation environmental fan linkage system has high monitoring accuracy in the actual application process.