{"title":"消防栓防护系统评估,以控制一栋面积为35190平方米的办公楼的火灾危险","authors":"Al Qadri, A. Pratama, J. H. Saragi, F. Sinaga, E. P. D. Boangmanalu","doi":"10.53695/jm.v4i1.891","DOIUrl":null,"url":null,"abstract":"In general, every building must be protected from fire hazards by passive and active fire protection systems. The application of a passive or active protection system is based on the function/classification, area, height, volume, building materials installed, and/or the number of building occupants. Therefore, we need a fire prevention system to reduce the impact and losses caused by fires. Fire Protection Systems are generally regulated by Permen PU 26/PRT/M/2008 concerning Technical Requirements for Fire Protection Systems in Buildings and the Environment, and then these requirements are grouped according to their respective aspects including, Hydrant Systems, pipe systems upright, Sprinkler System, and Smoke control system. The Hydrant Pump consists of Joekey 25 GPM, Electric and Diesel with a capacity of 1000 GPM","PeriodicalId":221886,"journal":{"name":"Jurnal MESIL (Mesin Elektro Sipil)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluasi Sistem Proteksi Hidrant sebagai Pengendalian Bahaya Kebakaran Pada Bangunan Perkantoran dengan Luas Bangunan 35.190 m2\",\"authors\":\"Al Qadri, A. Pratama, J. H. Saragi, F. Sinaga, E. P. D. Boangmanalu\",\"doi\":\"10.53695/jm.v4i1.891\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In general, every building must be protected from fire hazards by passive and active fire protection systems. The application of a passive or active protection system is based on the function/classification, area, height, volume, building materials installed, and/or the number of building occupants. Therefore, we need a fire prevention system to reduce the impact and losses caused by fires. Fire Protection Systems are generally regulated by Permen PU 26/PRT/M/2008 concerning Technical Requirements for Fire Protection Systems in Buildings and the Environment, and then these requirements are grouped according to their respective aspects including, Hydrant Systems, pipe systems upright, Sprinkler System, and Smoke control system. The Hydrant Pump consists of Joekey 25 GPM, Electric and Diesel with a capacity of 1000 GPM\",\"PeriodicalId\":221886,\"journal\":{\"name\":\"Jurnal MESIL (Mesin Elektro Sipil)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal MESIL (Mesin Elektro Sipil)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53695/jm.v4i1.891\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal MESIL (Mesin Elektro Sipil)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53695/jm.v4i1.891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
一般来说,每个建筑物都必须通过被动和主动防火系统来防止火灾危险。被动或主动防护系统的应用是基于功能/分类、面积、高度、体积、所安装的建筑材料和/或建筑物居住者的数量。因此,我们需要一个防火系统来减少火灾造成的影响和损失。消防系统一般是由Permen PU 26/PRT/M/2008《建筑和环境消防系统技术要求》进行规范,然后将这些要求按其各自的方面进行分组,包括:消火栓系统、直立管道系统、喷水灭火系统和防烟系统。消火栓泵由Joekey 25gpm,电动和柴油组成,容量为1000gpm
Evaluasi Sistem Proteksi Hidrant sebagai Pengendalian Bahaya Kebakaran Pada Bangunan Perkantoran dengan Luas Bangunan 35.190 m2
In general, every building must be protected from fire hazards by passive and active fire protection systems. The application of a passive or active protection system is based on the function/classification, area, height, volume, building materials installed, and/or the number of building occupants. Therefore, we need a fire prevention system to reduce the impact and losses caused by fires. Fire Protection Systems are generally regulated by Permen PU 26/PRT/M/2008 concerning Technical Requirements for Fire Protection Systems in Buildings and the Environment, and then these requirements are grouped according to their respective aspects including, Hydrant Systems, pipe systems upright, Sprinkler System, and Smoke control system. The Hydrant Pump consists of Joekey 25 GPM, Electric and Diesel with a capacity of 1000 GPM