神经网络在电压波动测量中的应用——神经网络闪变仪

M. Szlosek, B. Świątek, Z. Hanzelka
{"title":"神经网络在电压波动测量中的应用——神经网络闪变仪","authors":"M. Szlosek, B. Świątek, Z. Hanzelka","doi":"10.1109/ISNCC.2008.4627515","DOIUrl":null,"url":null,"abstract":"It can be shown, that many flickermeters do not yield credible output readings although the manufacturers declare their compliance with the requirements of standard IEC 61000-4-15. Modifications or revisions to the standard and increasing the number of requirements, what is currently taking place, seem to be interim actions, whose results are dubious. On the other hand, it should be acknowledged that since over ten years the standardization of voltage fluctuations is based on the UIE flickermeter. The authorspsila idea is to treat a flickermeter - from its analogue input to the output of block 4 - as a black box, filled in by a designer accordingly to its decision, while maintaining the IN/OUT characteristics in conformity with those of the flickermeter regarded as a standard one.","PeriodicalId":143815,"journal":{"name":"2008 International School on Nonsinusoidal Currents and Compensation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Application of neural networks to voltage fluctuations measurement — neural networks flickermeter\",\"authors\":\"M. Szlosek, B. Świątek, Z. Hanzelka\",\"doi\":\"10.1109/ISNCC.2008.4627515\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It can be shown, that many flickermeters do not yield credible output readings although the manufacturers declare their compliance with the requirements of standard IEC 61000-4-15. Modifications or revisions to the standard and increasing the number of requirements, what is currently taking place, seem to be interim actions, whose results are dubious. On the other hand, it should be acknowledged that since over ten years the standardization of voltage fluctuations is based on the UIE flickermeter. The authorspsila idea is to treat a flickermeter - from its analogue input to the output of block 4 - as a black box, filled in by a designer accordingly to its decision, while maintaining the IN/OUT characteristics in conformity with those of the flickermeter regarded as a standard one.\",\"PeriodicalId\":143815,\"journal\":{\"name\":\"2008 International School on Nonsinusoidal Currents and Compensation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International School on Nonsinusoidal Currents and Compensation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISNCC.2008.4627515\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International School on Nonsinusoidal Currents and Compensation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNCC.2008.4627515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

可以看出,尽管制造商声明其符合标准IEC 61000-4-15的要求,但许多闪烁计不能产生可靠的输出读数。目前正在进行的对标准的修改或修订和增加要求的数目似乎是临时行动,其结果是可疑的。另一方面,应该承认,由于十多年来电压波动的标准化是基于UIE闪变计的。作者的想法是把一个闪变表——从模拟输入到第4块的输出——当作一个黑盒子,由设计者根据自己的决定填充,同时保持与标准闪变表一致的输入/输出特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of neural networks to voltage fluctuations measurement — neural networks flickermeter
It can be shown, that many flickermeters do not yield credible output readings although the manufacturers declare their compliance with the requirements of standard IEC 61000-4-15. Modifications or revisions to the standard and increasing the number of requirements, what is currently taking place, seem to be interim actions, whose results are dubious. On the other hand, it should be acknowledged that since over ten years the standardization of voltage fluctuations is based on the UIE flickermeter. The authorspsila idea is to treat a flickermeter - from its analogue input to the output of block 4 - as a black box, filled in by a designer accordingly to its decision, while maintaining the IN/OUT characteristics in conformity with those of the flickermeter regarded as a standard one.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信