{"title":"横向磁场作用下高压直流分断过程中重击现象的实验研究","authors":"Cui Xinglei, Z. Xue, Chen Mo, Bo Kai, Peng Xiyuan","doi":"10.1109/HOLM.2015.7355095","DOIUrl":null,"url":null,"abstract":"In high-voltage direct-current relays, transverse magnetic field is widely used to reduce the arc erosion. Experiments showed that re-strike phenomenon always occurred during the arc-blowing process, which increased the arc duration and affected the normal breaking operation. In this paper, the arc-blowing process is investigated for 300~800V, 50A resistive load and special attentions are paid on re-strike phenomenon. The re-strike type, re-strike voltage and re-strike probability under different voltages are studied with the help of the arc images and arc voltage waveforms.","PeriodicalId":448541,"journal":{"name":"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Experiment research on re-strike phenomenon occurring during high-voltage direct-current breaking process under transverse magnetic field\",\"authors\":\"Cui Xinglei, Z. Xue, Chen Mo, Bo Kai, Peng Xiyuan\",\"doi\":\"10.1109/HOLM.2015.7355095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In high-voltage direct-current relays, transverse magnetic field is widely used to reduce the arc erosion. Experiments showed that re-strike phenomenon always occurred during the arc-blowing process, which increased the arc duration and affected the normal breaking operation. In this paper, the arc-blowing process is investigated for 300~800V, 50A resistive load and special attentions are paid on re-strike phenomenon. The re-strike type, re-strike voltage and re-strike probability under different voltages are studied with the help of the arc images and arc voltage waveforms.\",\"PeriodicalId\":448541,\"journal\":{\"name\":\"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2015.7355095\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2015.7355095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experiment research on re-strike phenomenon occurring during high-voltage direct-current breaking process under transverse magnetic field
In high-voltage direct-current relays, transverse magnetic field is widely used to reduce the arc erosion. Experiments showed that re-strike phenomenon always occurred during the arc-blowing process, which increased the arc duration and affected the normal breaking operation. In this paper, the arc-blowing process is investigated for 300~800V, 50A resistive load and special attentions are paid on re-strike phenomenon. The re-strike type, re-strike voltage and re-strike probability under different voltages are studied with the help of the arc images and arc voltage waveforms.