{"title":"低气压下人工冰覆盖污染绝缘子的交流闪络性能","authors":"L. Shu, M. Farzaneh, Y. Li, C. Sun","doi":"10.1109/CEIDP.2001.963617","DOIUrl":null,"url":null,"abstract":"In the present paper, the effects of several environmental parameters such as ice and low pressure on the electrical performance of short high voltage insulators were investigated. The arc characteristics and the relationship between the critical flashover voltage of the insulators and ice amount, pollution severity and air pressure were determined. The results obtained are helpful for the insulation design of transmission lines located at high altitudes.","PeriodicalId":112180,"journal":{"name":"2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"AC flashover performance of polluted insulators covered with artificial ice at low atmospheric pressure\",\"authors\":\"L. Shu, M. Farzaneh, Y. Li, C. Sun\",\"doi\":\"10.1109/CEIDP.2001.963617\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present paper, the effects of several environmental parameters such as ice and low pressure on the electrical performance of short high voltage insulators were investigated. The arc characteristics and the relationship between the critical flashover voltage of the insulators and ice amount, pollution severity and air pressure were determined. The results obtained are helpful for the insulation design of transmission lines located at high altitudes.\",\"PeriodicalId\":112180,\"journal\":{\"name\":\"2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2001.963617\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2001.963617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
AC flashover performance of polluted insulators covered with artificial ice at low atmospheric pressure
In the present paper, the effects of several environmental parameters such as ice and low pressure on the electrical performance of short high voltage insulators were investigated. The arc characteristics and the relationship between the critical flashover voltage of the insulators and ice amount, pollution severity and air pressure were determined. The results obtained are helpful for the insulation design of transmission lines located at high altitudes.