级联电路DSTATCOM直流电容电压控制策略研究

Zhou Yuan, Xia Mingchao
{"title":"级联电路DSTATCOM直流电容电压控制策略研究","authors":"Zhou Yuan, Xia Mingchao","doi":"10.1109/ISGT-ASIA.2012.6303184","DOIUrl":null,"url":null,"abstract":"The cascade DSTATCOM has been widely used in various DSTATCOM prototypes and projects due to its advantages such as low loss, high efficiency, little harmonic content in output voltage, easy modularization, and so on.However,this kind of DSTATCOM structure contains inherent unbalance capacitor voltage in the DC-link,which may lead to abnormal running of DSTATCOM,especially in the transient process running of DSTATCOM. Traditional DSTATCOM DC-bus voltage control strategy is three-level DC voltage control. However, when the DC capacitor of all the chain of three-phase circuit is lower than the target value, the first level control will firstly lose control function, then finally the voltage will be a serious imbalance. In this case, it cannot be achieved to the network voltage dynamic compensation.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A study on DC capacitor voltage control strategy of cascade circuit DSTATCOM\",\"authors\":\"Zhou Yuan, Xia Mingchao\",\"doi\":\"10.1109/ISGT-ASIA.2012.6303184\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The cascade DSTATCOM has been widely used in various DSTATCOM prototypes and projects due to its advantages such as low loss, high efficiency, little harmonic content in output voltage, easy modularization, and so on.However,this kind of DSTATCOM structure contains inherent unbalance capacitor voltage in the DC-link,which may lead to abnormal running of DSTATCOM,especially in the transient process running of DSTATCOM. Traditional DSTATCOM DC-bus voltage control strategy is three-level DC voltage control. However, when the DC capacitor of all the chain of three-phase circuit is lower than the target value, the first level control will firstly lose control function, then finally the voltage will be a serious imbalance. In this case, it cannot be achieved to the network voltage dynamic compensation.\",\"PeriodicalId\":330758,\"journal\":{\"name\":\"IEEE PES Innovative Smart Grid Technologies\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PES Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-ASIA.2012.6303184\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

级联DSTATCOM具有损耗低、效率高、输出电压谐波含量少、易于模块化等优点,已广泛应用于各种DSTATCOM样机和工程中。然而,这种DSTATCOM结构在直流链路中存在固有的电容电压不平衡,这可能导致DSTATCOM的异常运行,特别是在DSTATCOM的瞬态过程运行中。传统的DSTATCOM直流母线电压控制策略是三电平直流电压控制。但是,当三相电路全链直流电容低于目标值时,一级控制首先失去控制功能,最后电压出现严重不平衡。在这种情况下,无法实现对电网电压的动态补偿。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A study on DC capacitor voltage control strategy of cascade circuit DSTATCOM
The cascade DSTATCOM has been widely used in various DSTATCOM prototypes and projects due to its advantages such as low loss, high efficiency, little harmonic content in output voltage, easy modularization, and so on.However,this kind of DSTATCOM structure contains inherent unbalance capacitor voltage in the DC-link,which may lead to abnormal running of DSTATCOM,especially in the transient process running of DSTATCOM. Traditional DSTATCOM DC-bus voltage control strategy is three-level DC voltage control. However, when the DC capacitor of all the chain of three-phase circuit is lower than the target value, the first level control will firstly lose control function, then finally the voltage will be a serious imbalance. In this case, it cannot be achieved to the network voltage dynamic compensation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信