基于实际性能的100kw屋顶光伏并网型系统技术经济分析

Anam Khan, K. Rana
{"title":"基于实际性能的100kw屋顶光伏并网型系统技术经济分析","authors":"Anam Khan, K. Rana","doi":"10.1109/ICICT46931.2019.8977701","DOIUrl":null,"url":null,"abstract":"As more consideration is being centered around the improvement of sustainable power source assets all-inclusive, specialized and economic evaluations of these assets are vital to learning their feasibility. These evaluations can be increasingly significant on the off chance that they depend on field and real execution of the renewable resources source conversion resources. The present investigation shows a technical as well as economical examination of a 100 kW rooftop pv lattice associated framework dependent on practical implementation through homer programming. Both the yearly vitality created and devoured by the system is resolved. The examination of a matrix associated PV framework incorporates; Total Net Present Cost, Levelized Cost of Energy (Rs/kWh), level of sustainable energy (solar) utilized in structure, decrease in bill cost with these presentation parameters. The general, specialized exhibition of the network tied PV framework can be assessed and, they can likewise be utilized to contrast the display of any structure and comparative establishments, independent of their area and introduced limit and correlation with real information. The rate contrast between the genuine and determined power yields is around 11.26 %. However, further research needs to be done by planning a PV based framework for any building structure utilizing homer programming.","PeriodicalId":412668,"journal":{"name":"2019 International Conference on Issues and Challenges in Intelligent Computing Techniques (ICICT)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Techno-Economic Analysis of 100 kW Rooftop Photovoltaic Grid - Type System Based on Actual Performance through Homer Software\",\"authors\":\"Anam Khan, K. Rana\",\"doi\":\"10.1109/ICICT46931.2019.8977701\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As more consideration is being centered around the improvement of sustainable power source assets all-inclusive, specialized and economic evaluations of these assets are vital to learning their feasibility. These evaluations can be increasingly significant on the off chance that they depend on field and real execution of the renewable resources source conversion resources. The present investigation shows a technical as well as economical examination of a 100 kW rooftop pv lattice associated framework dependent on practical implementation through homer programming. Both the yearly vitality created and devoured by the system is resolved. The examination of a matrix associated PV framework incorporates; Total Net Present Cost, Levelized Cost of Energy (Rs/kWh), level of sustainable energy (solar) utilized in structure, decrease in bill cost with these presentation parameters. The general, specialized exhibition of the network tied PV framework can be assessed and, they can likewise be utilized to contrast the display of any structure and comparative establishments, independent of their area and introduced limit and correlation with real information. The rate contrast between the genuine and determined power yields is around 11.26 %. However, further research needs to be done by planning a PV based framework for any building structure utilizing homer programming.\",\"PeriodicalId\":412668,\"journal\":{\"name\":\"2019 International Conference on Issues and Challenges in Intelligent Computing Techniques (ICICT)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Issues and Challenges in Intelligent Computing Techniques (ICICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICT46931.2019.8977701\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Issues and Challenges in Intelligent Computing Techniques (ICICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICT46931.2019.8977701","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

随着越来越多的考虑集中在可持续能源资产的改进上,对这些资产进行全面的专业和经济评估对于了解其可行性至关重要。如果这些评价取决于可再生资源转换资源的现场和实际执行情况,那么这些评价就会越来越重要。目前的调查显示了100千瓦屋顶光伏格相关框架的技术和经济检查,依赖于通过荷马编程的实际实施。系统每年创造和消耗的活力都得到了解决。矩阵相关PV框架的检查包括;总净现值成本,能源平准化成本(Rs/kWh),结构中可持续能源(太阳能)的利用水平,通过这些表示参数降低账单成本。可以评估网络捆绑PV框架的一般、专业展示,也可以用来对比任何结构和比较机构的展示,而不受其面积和引入限制以及与真实信息的相关性的影响。真实功率和确定功率之间的比率差异约为11.26%。然而,进一步的研究需要通过规划一个基于PV的框架为任何建筑结构利用荷马编程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Techno-Economic Analysis of 100 kW Rooftop Photovoltaic Grid - Type System Based on Actual Performance through Homer Software
As more consideration is being centered around the improvement of sustainable power source assets all-inclusive, specialized and economic evaluations of these assets are vital to learning their feasibility. These evaluations can be increasingly significant on the off chance that they depend on field and real execution of the renewable resources source conversion resources. The present investigation shows a technical as well as economical examination of a 100 kW rooftop pv lattice associated framework dependent on practical implementation through homer programming. Both the yearly vitality created and devoured by the system is resolved. The examination of a matrix associated PV framework incorporates; Total Net Present Cost, Levelized Cost of Energy (Rs/kWh), level of sustainable energy (solar) utilized in structure, decrease in bill cost with these presentation parameters. The general, specialized exhibition of the network tied PV framework can be assessed and, they can likewise be utilized to contrast the display of any structure and comparative establishments, independent of their area and introduced limit and correlation with real information. The rate contrast between the genuine and determined power yields is around 11.26 %. However, further research needs to be done by planning a PV based framework for any building structure utilizing homer programming.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信