架空线路中压电网雷电引起的短时中断

M. Parviainen, P. Heine, M. Omidiora, M. Lehtonen, J. Niskanen, A. Oikarinen
{"title":"架空线路中压电网雷电引起的短时中断","authors":"M. Parviainen, P. Heine, M. Omidiora, M. Lehtonen, J. Niskanen, A. Oikarinen","doi":"10.1109/PQ.2008.4653751","DOIUrl":null,"url":null,"abstract":"Lightning strokes represent a considerable cause of short interruptions in overhead line medium voltage networks. The overvoltages caused by lightning can not be avoided but their influence can be limited by appropriate overvoltage protection. This paper presents the results of theoretical studies about the number of short interruptions caused by lightning in various environmental circumstances. The results will be compared to the fault statistics collected from Kainuun Energia. In the calculations, the environmental conditions, ground flash densities and various overvoltage protection types of power distribution transformers are taken into account. At the end, further research is discussed.","PeriodicalId":429968,"journal":{"name":"2008 Power Quality and Supply Reliability Conference","volume":"100 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Short interruptions caused by lightning in overhead line medium voltage networks\",\"authors\":\"M. Parviainen, P. Heine, M. Omidiora, M. Lehtonen, J. Niskanen, A. Oikarinen\",\"doi\":\"10.1109/PQ.2008.4653751\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning strokes represent a considerable cause of short interruptions in overhead line medium voltage networks. The overvoltages caused by lightning can not be avoided but their influence can be limited by appropriate overvoltage protection. This paper presents the results of theoretical studies about the number of short interruptions caused by lightning in various environmental circumstances. The results will be compared to the fault statistics collected from Kainuun Energia. In the calculations, the environmental conditions, ground flash densities and various overvoltage protection types of power distribution transformers are taken into account. At the end, further research is discussed.\",\"PeriodicalId\":429968,\"journal\":{\"name\":\"2008 Power Quality and Supply Reliability Conference\",\"volume\":\"100 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Power Quality and Supply Reliability Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PQ.2008.4653751\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Power Quality and Supply Reliability Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2008.4653751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在架空线路中压电网中,雷击是造成短时中断的一个重要原因。雷电引起的过电压是不可避免的,但通过适当的过电压保护可以限制其影响。本文介绍了各种环境条件下雷电短时中断次数的理论研究结果。结果将与凯努恩能源公司收集的故障统计数据进行比较。计算中考虑了环境条件、地闪密度和配电变压器各种过压保护类型。最后,对进一步的研究进行了展望。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Short interruptions caused by lightning in overhead line medium voltage networks
Lightning strokes represent a considerable cause of short interruptions in overhead line medium voltage networks. The overvoltages caused by lightning can not be avoided but their influence can be limited by appropriate overvoltage protection. This paper presents the results of theoretical studies about the number of short interruptions caused by lightning in various environmental circumstances. The results will be compared to the fault statistics collected from Kainuun Energia. In the calculations, the environmental conditions, ground flash densities and various overvoltage protection types of power distribution transformers are taken into account. At the end, further research is discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信