一种用于AHV体积连续测量的电极系统的研制

A. Shcherbachev, I. Kudashov, S. Shchukin, G. Itkin, Airat Galiamov, E. Bychkov
{"title":"一种用于AHV体积连续测量的电极系统的研制","authors":"A. Shcherbachev, I. Kudashov, S. Shchukin, G. Itkin, Airat Galiamov, E. Bychkov","doi":"10.18127/j15604136-202105-05","DOIUrl":null,"url":null,"abstract":"Mechanical circulatory assistance devices are vital for the patients with end-stage heart failure, who require heart transplantation but are in a waiting list due to the shortage of donor organs. This makes the development of the advanced MCS devices and artificial heart ventricles a crucial task. The systems for the dynamic and adaptive control of circulation parameters are required. AHV liquid volume measurement units must be developed to create such systems. Objective – Determination of the optimal electrode system for the AHV liquid volume measurement unit based on the electrical impedance measurements. The most significant geometrical parameters of the electrode systems for the impedance based AHV liquid volume measurement are determined. The optimal values of the geometrical parameters were found for the system of dynamic AHV liquid volume measurement. Results were confirmed by the numerical and experimental studies. The obtained values of the optimal geometrical parameters of electrode systems will be used in development of biotechnical system of adaptive AHV control.","PeriodicalId":169108,"journal":{"name":"Biomedical Radioelectronics","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an electrode system for continuous measurement of the volume of an AHV\",\"authors\":\"A. Shcherbachev, I. Kudashov, S. Shchukin, G. Itkin, Airat Galiamov, E. Bychkov\",\"doi\":\"10.18127/j15604136-202105-05\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mechanical circulatory assistance devices are vital for the patients with end-stage heart failure, who require heart transplantation but are in a waiting list due to the shortage of donor organs. This makes the development of the advanced MCS devices and artificial heart ventricles a crucial task. The systems for the dynamic and adaptive control of circulation parameters are required. AHV liquid volume measurement units must be developed to create such systems. Objective – Determination of the optimal electrode system for the AHV liquid volume measurement unit based on the electrical impedance measurements. The most significant geometrical parameters of the electrode systems for the impedance based AHV liquid volume measurement are determined. The optimal values of the geometrical parameters were found for the system of dynamic AHV liquid volume measurement. Results were confirmed by the numerical and experimental studies. The obtained values of the optimal geometrical parameters of electrode systems will be used in development of biotechnical system of adaptive AHV control.\",\"PeriodicalId\":169108,\"journal\":{\"name\":\"Biomedical Radioelectronics\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Radioelectronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18127/j15604136-202105-05\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Radioelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18127/j15604136-202105-05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

机械循环辅助装置对终末期心力衰竭患者至关重要,他们需要心脏移植,但由于供体器官短缺而在等待名单中。这使得开发先进的MCS装置和人工心脏心室成为一项至关重要的任务。对循环参数的动态和自适应控制系统提出了要求。必须开发AHV液体体积测量单元来创建这样的系统。目的:确定基于电阻抗测量的AHV液体体积测量单元的最佳电极系统。确定了基于阻抗的AHV液容测量电极系统最重要的几何参数。找到了动态AHV液容测量系统几何参数的最优值。数值和实验结果均证实了这一结论。所得电极系统的最优几何参数值将用于自适应AHV控制生物技术系统的开发。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of an electrode system for continuous measurement of the volume of an AHV
Mechanical circulatory assistance devices are vital for the patients with end-stage heart failure, who require heart transplantation but are in a waiting list due to the shortage of donor organs. This makes the development of the advanced MCS devices and artificial heart ventricles a crucial task. The systems for the dynamic and adaptive control of circulation parameters are required. AHV liquid volume measurement units must be developed to create such systems. Objective – Determination of the optimal electrode system for the AHV liquid volume measurement unit based on the electrical impedance measurements. The most significant geometrical parameters of the electrode systems for the impedance based AHV liquid volume measurement are determined. The optimal values of the geometrical parameters were found for the system of dynamic AHV liquid volume measurement. Results were confirmed by the numerical and experimental studies. The obtained values of the optimal geometrical parameters of electrode systems will be used in development of biotechnical system of adaptive AHV control.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信